ABB IRB 920 Product Manual page 511

Hide thumbs Also See for IRB 920:
Table of Contents

Advertisement

3
4
Refitting the flange to the ball screw shaft
1
2
3
Product manual - IRB 920
3HAC075721-001 Revision: C
Action
Refit the pulley to the ball screw carefully.
CAUTION
If the ball screw nut or ball screw spline nut go
out of the screw shaft, the ball screw is destroyed.
Be careful when you do any work that may cause
this.
Refit the screws.
Tip
Secure with the stopping tool to prevent the pulley
from rotating.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free. See
Cut the paint or surface on the robot
before replacing parts on page 118
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
Refit the ball screw flange to the ball screw shaft.
CAUTION
If the ball screw nut or ball screw spline nut go
out of the screw shaft, the ball screw is destroyed.
Be careful when you do any work that may cause
this.
Refit the screws.
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.6.5 Replacing the ball screw
Continued
Note
Screws: Hex socket head cap
screw M5x12 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Washers: Spring washer 9x4.3x1
Steel (6 pcs)
Tightening torque: 4.4 Nm ±10%
xx2100001085
Note
Screws: Hex socket head cap
screw M4x16 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Tightening torque: 3.5 Nm ±10%
xx2100001090
Continues on next page
511

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 920 seriesIrb 920-6/0.55Irb 920-6/0.65Irb 920t-6/0.45Irb 920t-6/0.55Irb 920t-6/0.65