5 Repair
5.8.1 Replacing the axis-1 gear unit sub-assembly
Continued
Required tools and equipment
Equipment
Standard toolkit
Calibration toolbox, Axis Calibra-
tion
Belt tension adjustment tool set,
axis 1&2
Sonic tension meter
Handheld dynamometer
Required consumables
Consumable
Cable straps
Grease
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Continues on next page
844
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
© Copyright 2022 ABB. All rights reserved.
Article number
Note
-
Content is defined in section
Standard toolkit on page
3HAC055412-001
Delivered as a set of calibration
tools.
Required if Axis Calibration is the
valid calibration method for the
robot.
-
Included in the special toolkit
3HAC073070-001.
Used to adjust the tension of axis-
1&2 timing belts.
Special tool for L2
-
Used for measuring the timing
belt tension.
-
Used for measuring the timing
belt tension.
Article number
Note
-
3HAC029132-001
FM 222
Note
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
routine on page
996.
Reference calibration
957.
Product manual - IRB 920
3HAC075721-001 Revision: C