ABB IRB 920 Product Manual page 663

Hide thumbs Also See for IRB 920:
Table of Contents

Advertisement

4
5
6
Product manual - IRB 920
3HAC075721-001 Revision: C
Action
For robots with C1 cabling
Disconnect the connector.
R2.C1
For robots with C2 cabling
Disconnect the connector.
R1.C2
Tip
Cut the cable straps for the R1.C2 at the same
time.
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Tip
The connector clip has to be pressed (1) and
pushed forward (2) to separate the R1.C2 (for C2
cabling).
xx1800002943
Snap loose and remove the female head of the
connectors from the bracket.
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.6.11 Replacing the outer arm
Continued
Note
xx2100001033
xx2100001034
Continues on next page
663