ABB IRB 920 Product Manual page 815

Hide thumbs Also See for IRB 920:
Table of Contents

Advertisement

For Clean Room/ IP54 robots
Refitting the top cover and the flange with bearing
1
2
3
Product manual - IRB 920
3HAC075721-001 Revision: C
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free. See
Cut the paint or surface on the robot
before replacing parts on page 118
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Install the flange with bearing to the extension
shaft.
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Refit the screws to the flange with bearing.
© Copyright 2022 ABB. All rights reserved.
5.7.3 Replacing the axis-3 motor sub-assembly
Note
xx2100002402
Screws: Hex socket head cap
screw M2.5x6 12.9 Lafre
2C2B/FC6.9 (8 pcs)
Tightening torque: 0.8 Nm ±10%
xx2100002401
5 Repair
Continued
Continues on next page
815

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 920 seriesIrb 920-6/0.55Irb 920-6/0.65Irb 920t-6/0.45Irb 920t-6/0.55Irb 920t-6/0.65

Table of Contents