ABB IRB 920 Product Manual page 431

Hide thumbs Also See for IRB 920:
Table of Contents

Advertisement

6
Removing the lower bellow
1
2
3
4
Product manual - IRB 920
3HAC075721-001 Revision: C
Action
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Remove the flange with bearing.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
118.
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Loosen the upper bellow clamp by loosening the
screw and pull the clamp apart slightly.
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Remove the bellow from the outer arm.
Note
For robots with protection class IP54 (option 3350-
540)
Clean the bellow from the glue if it will be reused.
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.6.2 Replacing the bellows
Continued
Note
xx2100002407
Note
xx2100002408
Continues on next page
431

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 920 seriesIrb 920-6/0.55Irb 920-6/0.65Irb 920t-6/0.45Irb 920t-6/0.55Irb 920t-6/0.65