ABB IRB 920 Product Manual page 523

Hide thumbs Also See for IRB 920:
Table of Contents

Advertisement

3
4
5
Product manual - IRB 920
3HAC075721-001 Revision: C
Action
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Secure the shaft to the ball screw with the screws.
For robots with protection class IP54 (option 3350-
540)
Apply the glue to the upper contacted zone
between the shaft and the ball screw.
Note
Fulfill the gaps on the ball screw in this contacted
zone to make a sealing structure.
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Insert the O-ring to the shaft.
Note
Replace the o-ring if needed.
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.6.5 Replacing the ball screw
Continued
Note
Screws: Hexagon socket set
screws with flat point, ISO 4026
stainless steel M3x8 (2 pcs)
Tightening torque: 0.4 Nm ±10%
xx1900001616
xx1900001805
xx1900001615
Continues on next page
523

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 920 seriesIrb 920-6/0.55Irb 920-6/0.65Irb 920t-6/0.45Irb 920t-6/0.55Irb 920t-6/0.65

Table of Contents