3
Refitting the axis-1 cover
1
Product manual - IRB 920
3HAC075721-001 Revision: C
Action
Secure the process hub to the outer arm cover
with the screws.
Note
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Check the gasket for the process hub.
Tip
Replace the gasket if needed.
CAUTION
Be aware of the cabling that is attached to the
cover! The cover can not be removed completely
until the connectors are disconnected, as shown
in following steps.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free. See
Cut the paint or surface on the robot
before replacing parts on page 118
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
© Copyright 2022 ABB. All rights reserved.
5.7.1 Replacing the axis-1 motor sub-assembly
Note
Screws: Hex socket head cap
screw M4x10 12.9 Lafre
2C2B/FC6.9 (5 pcs)
Tightening torque: 2.6 Nm±10%
For robots with protection class
IP30 (option 3350-300)
xx2100000932
For robots with protection class
IP54 (option 3350-540)
For robots with protection type
Clean Room (option 3351-1)
xx2100002438
Note
5 Repair
Continued
Continues on next page