5 Repair
5.4.1 Replacing the base
Continued
Disconnecting the connector for PB
1
2
3
4
Pull out the process hub
1
Continues on next page
214
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
118.
Disconnect the connector.
R2.PB
R2.LAMP
Snap loose and remove the female head of the
connector from the bracket.
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
© Copyright 2022 ABB. All rights reserved.
Note
xx2100001030
xx2100001031
Note
Product manual - IRB 920