It is possible to position some of the other axes in positions different from 0 degrees.
Information about which axes are allowed to be jogged is given on the FlexPendant.
These axes are marked with Unrestricted in the FlexPendant window. Also the
following table shows the dependencies between the axes.
Requirements for axis positioning during calibration
Required
position of
axis
Axis 1
Axis 2
Axis 3
Axis 4
Axis 5
-
*
0
X
Product manual - IRB 390
3HAC066566-001 Revision: B
Axis to calibrate
Axis 1
Axis 2
-
X
X
-
X
X
*
*
*
*
Axis to be calibrated
Unrestricted. Axis is allowed to be jogged to other position than 0 degrees.
Axis must be put in position 0 degrees.
Special requirement
© Copyright 2020 - 2021 ABB. All rights reserved.
6.4.1 Description of Axis Calibration
Axis 3
Axis 4
X
*
X
*
-
*
*
-
*
*
6 Calibration
Continued
Axis 5
Axis 6
*
*
*
0
-