Changing oil in the gear unit pre-stage
Use this procedure to drain the gear unit pre-stage.
Removing the gear unit pre-stage
1
Changing oil in the gear unit pre-stage
1
2
3
4
Refitting the gear unit pre-stage
1
Product manual - IRB 390
3HAC066566-001 Revision: B
4.4.4 Changing oil, axis-4 and axis-5 gear unit pre-stage
Action
Remove the gear unit pre-stage from the base
unit according to:
Replacing the axis-4 gear unit pre-stage on
page 265
Replacing the axis-5 gear unit pre-stage on
page 281
Action
WARNING
Handling gearbox oil involves several safety risks,
see
Gearbox lubricants (oil or grease) on page
Dispose the gear oil in a safe way.
WARNING
Used oil is hazardous material and must be dis-
posed of in a safe way. See
page 327
for more information.
Fill new oil into the gear unit.
Action
Refit the gear unit pre-stage to the base unit ac-
cording to:
Replacing the axis-4 gear unit pre-stage on
page 265
Replacing the axis-5 gear unit pre-stage on
page 281
© Copyright 2020 - 2021 ABB. All rights reserved.
Note
Note
30.
Decommissioning on
Information about the type of lubric-
ation, article number as well as the
amount in the specific gearbox can
be found in Technical reference
manual - Lubrication in gearboxes
available for registered users on
myABB Business Portal,
www.abb.com/myABB.