C3206 Incorrect input for power

C3207 Type plate list incomplete

Cause
List length of parameter P-0-4032, Type plate list
asynchronous motor is shorter than 6 elements or
at least one element has value "0"
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
During the execution of the command P-0-4033, C3200 Command
Calculate data for asynchronous motor an error was detected.
Cause:
There is no useful relation between list element 6 (rated power) in
P-0-4032, Type plate list asynchronous motor and electric power that
results from the other rated data.
Effective electric power of an asynchronous motor results from
rated
current
Fig. 9-2:
Effective electric power of an asynchronous motor
Mechanical power output has to be smaller than above value because an
efficiency of less than 1 is assumed. Furthermore a mechanical power
output smaller than 40% of effective electric power is not plausible.
Remedy:
Correct values in P-0-4032, Type plate list asynchronous motor and
restart command P-0-4033, C3200 Command Calculate data for
asynchronous motor.
C3206 - Attributes
Display:
C3206
Mess. no.:
C3206 (hex)
Supported by Firmware Variant:
During the execution of the command P-0-4033, C3200 Command
Calculate data for asynchronous motor an error was detected.
Remedy
Please check: To calculate motor and controller
parameters from type plate of an asynchronous motor,
value higher than "0" has to be entered in all 6 list
elements of P-0-4032, Type plate list asynchronous
motor
C3207 - Attributes
Display:
C3207
Mess. no.:
C3207 (hex)
Command Diagnostic Messages
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
ϕ
×
×
rated
voltage
cos
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
9-115
×
1.5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rexroth IndraDrive and is the answer not in the manual?

Questions and answers

Kaushal patel
January 25, 2025

Our machine in Rexroth drive installation total 20 nos machine so facing issue shortly 5 drive folty 8060 erro so how to do

1 comments:
Mr. Anderson
February 10, 2025

Error 8060 on Bosch Rexroth IndraDrive indicates an overcurrent in the power section. To resolve this issue for five machines, follow these steps for each machine:

1. Check the Load and Connections – Verify that the motor and power connections are correct and not causing excessive current draw.
2. Inspect the Power Section – Look for any visible damage or overheating signs in the power section.
3. Restart the System – Power off the drive, wait for the DC bus to discharge below 50V, and restart.
4. Adjust Parameters if Needed – Ensure that the drive’s current limits and motor settings are correctly configured.
5. Replace Faulty Components – If the issue persists, the power section may be defective and require replacement.

Repeat these steps for all five machines to ensure proper operation.