C2600 Copy IDN from internal memory to optional memory

C2800 Analog input adjust command

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
The command P-0-4092, C2600 Copy IDN from internal memory to
optional memory was started.
All parameters are copied from the internal memory (flash) to the optional
memory (MMC).
The display "C26" signals that the command is executed and the
parameters are written from the drive to the MMC.
Note:
The MMC can only be used as an optional memory for control
sections with MMC slot.
See
also
Functional
Parameters"
C2600 - Attributes
Display:
C26
Mess. no.:
C2600 (hex)
Supported by Firmware Variant:
By executing the command P-0-0220, C2800 Analog input adjust
command it is possible to carry out an automatic adjust (zero point and
gain) of the analog input.
Note:
The command is controlled by the settings in P-0-0218,
Analog input, control parameter.
See also Functional Description "Analog Inputs"
C2800 - Attributes
Display:
C28
Mess. no.:
C2800 (hex)
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
Description
"Loading,
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive
Storing
and
Saving

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rexroth IndraDrive and is the answer not in the manual?

Questions and answers

Kaushal patel
January 25, 2025

Our machine in Rexroth drive installation total 20 nos machine so facing issue shortly 5 drive folty 8060 erro so how to do

1 comments:
Mr. Anderson
February 10, 2025

Error 8060 on Bosch Rexroth IndraDrive indicates an overcurrent in the power section. To resolve this issue for five machines, follow these steps for each machine:

1. Check the Load and Connections – Verify that the motor and power connections are correct and not causing excessive current draw.
2. Inspect the Power Section – Look for any visible damage or overheating signs in the power section.
3. Restart the System – Power off the drive, wait for the DC bus to discharge below 50V, and restart.
4. Adjust Parameters if Needed – Ensure that the drive’s current limits and motor settings are correctly configured.
5. Replace Faulty Components – If the issue persists, the power section may be defective and require replacement.

Repeat these steps for all five machines to ensure proper operation.

This answer is automatically generated