Rexroth IndraDrive
C07_2 Load def. proc. com. (load def. pr. for safety techn.)
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
The C07_2 message on the display of the drive controller shows that the
C07_2 Load def. proc. com. (load def. pr. for safety techn.) command
was activated.
The command can be started as follows:
1. Enter value 165 for "load defaults procedure for safety technology" in
parameter P-0-4090, Index for C07 Load defaults procedure
2. Start S-0-0262, C07_x Load defaults procedure command
Note:
It is possible to start further commands with parameter
S-0-0262. In parameter P-0-4090, Index for C07 Load
defaults procedure it is possible to set which commands is
started.
The command C07_2 Load def. proc. com. (load def. pr. for safety
techn.) deactivates the safety technology and sets all safety technology
parameters to their default value.
The command C07_2 Load def. proc. com. (load
def. pr. for safety techn.) overwrites user-
defined safety technology settings!
⇒ Only use this command if you want to commission
CAUTION
safety technology again.
C0720 - Attributes
Display:
C07_2
Mess. no.:
C0720 (hex)
Command Diagnostic Messages
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
9-5
Need help?
Do you have a question about the Rexroth IndraDrive and is the answer not in the manual?
Questions and answers
Our machine in Rexroth drive installation total 20 nos machine so facing issue shortly 5 drive folty 8060 erro so how to do
Error 8060 on Bosch Rexroth IndraDrive indicates an overcurrent in the power section. To resolve this issue for five machines, follow these steps for each machine:
1. Check the Load and Connections – Verify that the motor and power connections are correct and not causing excessive current draw.
2. Inspect the Power Section – Look for any visible damage or overheating signs in the power section.
3. Restart the System – Power off the drive, wait for the DC bus to discharge below 50V, and restart.
4. Adjust Parameters if Needed – Ensure that the drive’s current limits and motor settings are correctly configured.
5. Replace Faulty Components – If the issue persists, the power section may be defective and require replacement.
Repeat these steps for all five machines to ensure proper operation.
This answer is automatically generated
What is solution of 2110 fault in rexroth drive
The solution for the F2110 fault in Bosch Rexroth IndraDrive is:
1. If the failure occurs sporadically (firmware error), clear the error and contact the service department for a firmware update.
2. If the error occurs repeatedly, it indicates defective hardware. In this case, the control section or the entire device must be replaced.
3. Only Rexroth service engineers or specially trained users are allowed to replace the control section.
4. The procedure for replacing the entire drive controller is described in the Project Planning Manual for the power section.
This answer is automatically generated
The engine moves in manual mode but does not work in automatic mode. The error code is E2074. What should I do?
Error code F2074 indicates a defective motor encoder. To resolve this issue:
1. Check the position data reference – If the position data reference is incorrect, the encoder is defective.
2. Replace the motor or motor encoder – A faulty encoder can prevent movement in automatic mode.
3. Send the motor to the manufacturer’s service department for inspection.
If the issue persists, consult the service department for further assistance.
This answer is automatically generated