E2814 Undervoltage In Mains - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

8-42
Warning Diagnostic Messages (Exxxx)

E2814 Undervoltage in mains

Cause
Mains voltage falls under load
Mains voltage too low at power on
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
Supported by Supply Unit:
Note:
This warning only occurs for drive controllers of the HCS03
type!
The crest value of the mains voltage during operation has fallen below the
parameterized threshold value. The threshold value can be individually set
by the user via P-0-0810, Minimum mains crest value.
Remedy
Check dimensioning of mains connection, increase feed
wire cross section or use matching transformer, if
necessary
Use matching transformer
See also Functional Description "Power Supply"
E2814 - Attributes
Display:
E2814
Mess. no.:
E2814 (hex)
Rexroth IndraDrive
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
HMV01
DOK-INDRV*-GEN-**VRS**-WA01-EN-P

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents