F2014 Plc - Error Nr. 4 - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

7-82
Error Messages

F2014 PLC - Error nr. 4

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
In conjunction with technology functions the PLC integrated in the drive
(optional expansion package "drive PLC") allows the user generating error
messages (F2011...F2014) within the PLC program.
The causes of the error are depending on the respective PLC project (or
the active technology function). If the error message is generated by a
technology function made available by Bosch Rexroth, the causes and
remedies are contained in the description of the technology function.
See also documentation "Rexroth IndraMotion MLD-S"
F2014 - Attributes
Display:
F2014
Mess. no.:
F2014 (hex)
Rexroth IndraDrive
FWA-INDRV*-MPH02VRS-MS
DOK-INDRV*-GEN-**VRS**-WA01-EN-P

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rexroth IndraDrive and is the answer not in the manual?

Questions and answers

Kaushal patel
January 25, 2025

Our machine in Rexroth drive installation total 20 nos machine so facing issue shortly 5 drive folty 8060 erro so how to do

1 comments:
Mr. Anderson
February 10, 2025

Error 8060 on Bosch Rexroth IndraDrive indicates an overcurrent in the power section. To resolve this issue for five machines, follow these steps for each machine:

1. Check the Load and Connections – Verify that the motor and power connections are correct and not causing excessive current draw.
2. Inspect the Power Section – Look for any visible damage or overheating signs in the power section.
3. Restart the System – Power off the drive, wait for the DC bus to discharge below 50V, and restart.
4. Adjust Parameters if Needed – Ensure that the drive’s current limits and motor settings are correctly configured.
5. Replace Faulty Components – If the issue persists, the power section may be defective and require replacement.

Repeat these steps for all five machines to ensure proper operation.

This answer is automatically generated