Bosch Rexroth IndraDrive Troubleshooting Manual page 12

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

Rexroth IndraDrive
E2075 Encoder 2: encoder signals disturbed ........................................................................ 8-37
E2076 Measuring encoder: encoder signals disturbed ......................................................... 8-38
E2086 Prewarning supply module overload .......................................................................... 8-39
E2800 DC bus timeout........................................................................................................... 8-39
E2802 HW control braking resistor ........................................................................................ 8-40
E2810 Drive system not ready for operation ......................................................................... 8-41
E2814 Undervoltage in mains................................................................................................ 8-42
E2815 Overvoltage in mains.................................................................................................. 8-43
E2816 Undervoltage in power section ................................................................................... 8-43
E2818 Phase failure............................................................................................................... 8-44
E2819 Mains failure ............................................................................................................... 8-44
E2820 Braking resistor overload prewarning......................................................................... 8-45
E2829 Not ready for power on ............................................................................................... 8-45
9
9.1
Commands.................................................................................................................................... 9-1
C0100 Communication phase 3 transition check .................................................................... 9-1
C0200 Communication phase 4 transition check .................................................................... 9-1
C0300 Command Set absolute measuring.............................................................................. 9-2
C0400 Switching to parameter mode ...................................................................................... 9-2
C0500 Reset class 1 diagnostics, error reset .......................................................................... 9-3
C0600 Drive-controlled homing procedure command ............................................................. 9-3
C07_0 Load defaults procedure com. (load controller param.) ............................................... 9-4
C07_2 Load def. proc. com. (load def. pr. for safety techn.) ................................................... 9-5
C07_1 Load defaults procedure com. (load basic parameters) .............................................. 9-6
C0800 Load basic parameters command................................................................................ 9-6
C0900 Position spindle command ........................................................................................... 9-6
C1200 Commutation offset setting command.......................................................................... 9-7
C1300 Positive stop drive procedure command...................................................................... 9-7
C1400 Command Get marker position .................................................................................... 9-8
C1700 Command measuring wheel mode .............................................................................. 9-8
C1800 Command automatic control loop setting..................................................................... 9-9
C2000 Command Release motor holding brake ................................................................... 9-10
C2100 Brake check command............................................................................................... 9-10
C2200 Backup working memory procedure command.......................................................... 9-10
C2300 Load working memory command ............................................................................... 9-11
C2400 Selectively backup working memory procedure command........................................ 9-11
C2500 Copy IDN from optional memory to internal memory................................................. 9-11
C2600 Copy IDN from internal memory to optional memory................................................. 9-12
C2800 Analog input adjust command.................................................................................... 9-12
C2900 Command Firmware update from MMC..................................................................... 9-13
C3000 Synchronize and store safety technology IDN ........................................................... 9-13
C3100 Recalculate actual value cycle ................................................................................... 9-14
C3200 Command Calculate data for asynchronous motor.................................................... 9-14
C3300 Set coordinate system procedure command ............................................................. 9-15
C3400 Shift coordinate system procedure command............................................................ 9-15
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
IX
Contents
9-1

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rexroth IndraDrive and is the answer not in the manual?

Questions and answers

Kaushal patel
January 25, 2025

Our machine in Rexroth drive installation total 20 nos machine so facing issue shortly 5 drive folty 8060 erro so how to do

1 comments:
Mr. Anderson
February 10, 2025

Error 8060 on Bosch Rexroth IndraDrive indicates an overcurrent in the power section. To resolve this issue for five machines, follow these steps for each machine:

1. Check the Load and Connections – Verify that the motor and power connections are correct and not causing excessive current draw.
2. Inspect the Power Section – Look for any visible damage or overheating signs in the power section.
3. Restart the System – Power off the drive, wait for the DC bus to discharge below 50V, and restart.
4. Adjust Parameters if Needed – Ensure that the drive’s current limits and motor settings are correctly configured.
5. Replace Faulty Components – If the issue persists, the power section may be defective and require replacement.

Repeat these steps for all five machines to ensure proper operation.

This answer is automatically generated

Table of Contents