E3103 Dynamization Failed; E3104 Plausibility Error Of Safety Parameters - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

8-16
Warning Diagnostic Messages (Exxxx)

E3103 Dynamization failed

Cause
There doesn't occur any dynamization pulse at the
dynamization input within the time P-0-3223, Time
interval for dynamization of safety function
selection or the pulse width differs from the
parameterized time P-0-3224, Duration of
dynamization pulse of safety function selection

E3104 Plausibility error of safety parameters

Cause
A comparison has shown that channel 1 and
channel 2 are not working with the same safety
parameters
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety function is selected, the cause of the
error causes the error F3134 Dynamization time interval incorrect or
F3135 Dynamization pulse width incorrect to be triggered.
Remedy
Remove cause of error in wiring of dynamization input
E3103 - Attributes
Display:
E3103
Mess. no.:
E3103 (hex)
Supported by Firmware Variant:
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety function is selected, the cause of the
error causes the error F3140 Plausibility error of safety parameters to
be triggered.
Remedy
Execute command P-0-3204, Synchronize and store
safety technology IDN command; channel 2 thereby
accepts parameters of channel 1
E3104 - Attributes
Display:
E3104
Mess. no.:
E3104 (hex)
Rexroth IndraDrive
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
DOK-INDRV*-GEN-**VRS**-WA01-EN-P

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents