C0258 Error In Relation Tncyc (S-0-0001) To Fine Interpol - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

9-66
Command Diagnostic Messages

C0258 Error in relation TNcyc (S-0-0001) to fine interpol.

Cause
S-0-0001, NC cycle time (TNcyc) incorrectly
parameterized
Cubic fine interpolation or fine interpolation
according to contour cannot be used with present
NC cycle time (S-0-0001, NC cycle time TNcyc))
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
During
the
transition
communication phase 4 (C0200) a check is run, when the cubic fine
interpolator or the interpolator according to contour (P-0-0187, Position
command processing mode = 1 or 2) is used, to find out whether the
selected NC cycle time is supported by the respective fine interpolator.
Remedy
Select appropriate S-0-0001, NC cycle time TNcyc).
Allowed NC cycle times, when using cubic fine
interpolator or fine interpolator according to contour, are:
1, 2, 3, 4, 5, 6, 7, 8 ms for S-0-0001 <= 8 ms
10, 12, 14, 16 ms for S-0-0001 <= 16 ms
20, 24, 28, 32 ms for S-0-0001 <= 32 ms
Use linear fine interpolator (P-0-0187, Position
command processing mode = 0)
For removing command errors see "Command Errors"
C0258 - Attributes
Display:
C0258
Mess. no.:
C0258 (hex)
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
check
from
communication
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive
phase 3
to

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rexroth IndraDrive and is the answer not in the manual?

Questions and answers

Kaushal patel
January 25, 2025

Our machine in Rexroth drive installation total 20 nos machine so facing issue shortly 5 drive folty 8060 erro so how to do

Table of Contents

Save PDF