E3105 Plausibility Error Of Safety Related Operating Mode; E3106 System Error Channel 2 - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

Rexroth IndraDrive

E3105 Plausibility error of safety related operating mode

Cause
During comparison of active safety function of
channel 1 and channel 2 a difference was detected
for more than 5 seconds

E3106 System error channel 2

Cause
System error on channel 2
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety function is selected, the cause of the
error causes the error F7042 Plausibility error safety related operating
mode to be triggered.
Remedy
Reboot drive. If drive generates warning again,
hardware has to be replaced
E3105 - Attributes
Display:
E3105
Mess. no.:
E3105 (hex)
Supported by Firmware Variant:
When the safety technology has been activated, this warning only occurs
in normal operation. When a safety function is selected, the cause of the
error causes the error F3146 System error channel 2 to be triggered.
Remedy
Reset module, replace hardware if error occurs
repeatedly
E3106 - Attributes
Display:
E3106
Mess. no.:
E3106 (hex)
Warning Diagnostic Messages (Exxxx)
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
8-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents