Bosch Rexroth IndraDrive Troubleshooting Manual page 420

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
list of diagnostic numbers 1-4
structure 1-2
diagnostic message number 1-3
diagnostic messages in plain text 1-3
diagnostic system 1-1
Dig. I/Os
bit number too large 9-62
Dig. output already assigned to other axis 9-61
displaying the diagnostic message number 1-3
Distance home switch - reference mark erroneous 9-71
Double MDT failure shutdown 7-51
Double MST failure shutdown 7-50
Drive active, switching not allowed 9-69
Drive controlled interpolation, encoder 1 6-15
Drive controlled interpolation, encoder 2 6-15
Drive controlled interpolation, lagless, encoder 1 6-16
Drive controlled interpolation, lagless, encoder 2 6-16
Drive deceleration to standstill 6-37
Drive HALT 6-5
Drive in automatic mode 6-38
Drive in TORQUE control 6-12
Drive in VELOCITY control 6-12
Drive interlock active 6-8
Drive is still in drive enable 9-112
Drive system not ready for operation 8-12
Drive system not ready for operation 8-41
Drive-controlled homing procedure command 9-3
Drive-controlled positioning, encoder 1 6-26
Drive-controlled positioning, encoder 1, lagless 6-27
Drive-controlled positioning, encoder 2 6-28
Drive-controlled positioning, encoder 2, lagless 6-29
Dynamization failed 8-16
Dynamization pulse width incorrect 7-66
Dynamization time interval incorrect 7-65
E
Emergency-Stop 7-56, 8-5
Emergency-Stop activated 7-45
Enc. 1
enc. signals incorr. (can be cleared in ph. 2) 7-13
Encoder 1
encoder signals disturbed 8-36
Encoder 2
encoder signals disturbed 8-37
encoder signals incorrect 7-94
End C29 4-3
Error at init. of synchr. motor with reluctance torque 9-41
Error balancing monitor/ground fault 7-126
error classes 1-16
Error clearing only in parameter mode 9-70
Error during abrasion of brake 9-120
Error during initialization 9-82
Error during initialization of control section 7-19
Error during initialization of motor data (->S-0-0021) 9-38
Error during phase progression 7-52
Error during phase regression 7-53
Error during safety related homing procedure 9-121
Error during search for zero pulse 9-82
Error during synchronization to master communication 9-63
Error in control of braking resistor 7-124
Error in non-cyclical data communic. of power section 7-114
Error in offset calculation 9-83
Error in relation TNcyc (S-0-0001) to fine interpol. 9-66
Error internal function call 7-3
Error internal RTOS function call 7-3
Error mechanical link of encoder or motor connection 7-14
error number 1-4
Error of output stage interlock 7-39
Error supply module 7-108
13-3
Index

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rexroth IndraDrive and is the answer not in the manual?

Questions and answers

Kaushal patel
January 25, 2025

Our machine in Rexroth drive installation total 20 nos machine so facing issue shortly 5 drive folty 8060 erro so how to do

1 comments:
Mr. Anderson
February 10, 2025

Error 8060 on Bosch Rexroth IndraDrive indicates an overcurrent in the power section. To resolve this issue for five machines, follow these steps for each machine:

1. Check the Load and Connections – Verify that the motor and power connections are correct and not causing excessive current draw.
2. Inspect the Power Section – Look for any visible damage or overheating signs in the power section.
3. Restart the System – Power off the drive, wait for the DC bus to discharge below 50V, and restart.
4. Adjust Parameters if Needed – Ensure that the drive’s current limits and motor settings are correctly configured.
5. Replace Faulty Components – If the issue persists, the power section may be defective and require replacement.

Repeat these steps for all five machines to ensure proper operation.

This answer is automatically generated

Ashok Kumar sharma
March 3, 2025

What is solution of 2110 fault in rexroth drive

1 comments:
Mr. Anderson
March 3, 2025

The solution for the F2110 fault in Bosch Rexroth IndraDrive is:

1. If the failure occurs sporadically (firmware error), clear the error and contact the service department for a firmware update.
2. If the error occurs repeatedly, it indicates defective hardware. In this case, the control section or the entire device must be replaced.
3. Only Rexroth service engineers or specially trained users are allowed to replace the control section.
4. The procedure for replacing the entire drive controller is described in the Project Planning Manual for the power section.

This answer is automatically generated

Aleksandır
March 12, 2025

The engine moves in manual mode but does not work in automatic mode. The error code is E2074. What should I do?

2 comments:
Mr. Anderson
March 12, 2025

Error code F2074 indicates a defective motor encoder. To resolve this issue:

1. Check the position data reference – If the position data reference is incorrect, the encoder is defective.
2. Replace the motor or motor encoder – A faulty encoder can prevent movement in automatic mode.
3. Send the motor to the manufacturer’s service department for inspection.

If the issue persists, consult the service department for further assistance.

This answer is automatically generated

Stephen
March 21, 2025

@Aleksand C0209incorrect encoder configuration error on drive controller display, red light fickering on drive comms port,

Mr.zuma
March 19, 2025

Please help me with the problem of the VM F2802 and E2810 errors on the Rexroth Indradrive M

User image 67da6c3815881
1 comments:
Mr. Anderson
March 19, 2025

The VM F2802 error on the Bosch Rexroth IndraDrive M indicates that the Phase-Locked Loop (PLL) is not synchronized.

The E2810 error means that the drive system is not ready for operation. This occurs when one or more drives in a system (connected via DC bus and module bus) signal an error, preventing the supply from being ready for power output. To resolve it, identify the drives signaling an error and remove the cause, or ensure all drives are in communication phase 4.

This answer is automatically generated

Saleh
March 27, 2025

Medodyjsjddidi

User image 67e59d0957d0e