C0607 Reference Cam Input Not Assigned; C0702 Default Parameters Not Available - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

9-74
Command Diagnostic Messages

C0607 Reference cam input not assigned

Cause
Home switch hasn't been assigned to any digital
input

C0702 Default parameters not available

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
During the execution of the "Drive-controlled homing procedure"
command (C0600) an error was detected.
Remedy
Assign home switch (S-0-0400, Home switch) to a
digital input via parameter P-0-0300, Digital I/Os,
assignment list
C0607 - Attributes
Display:
C0607
Mess. no.:
C0607 (hex)
Supported by Firmware Variant:
During the execution of the C07_0 Load defaults procedure com. (load
controller param.) command an error occurred.
Cause:
The control loops, in the case of motors of the MHD, MKD and MKE
series, are adjusted to the connected digital drive by activating the
controller parameters stored in the motor encoder data memory. The
C0702 message on the display of the drive controller signals that there
isn't any data memory available at the connected motor.
Remedy:
Data sheets of Rexroth Indramat motors are made available by the
service department. Enter the controller parameters.
See
also
Functional
Parameters"
See also Functional Description "Rexroth Housing Motors with Encoder
Data Memory"
C0702 - Attributes
Display:
C0702
Mess. no.:
C0702 (hex)
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
Description
"Loading,
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive
Storing
and
Saving

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents