C1218 Automatic Commutation: Current Too Low - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

9-88
Command Diagnostic Messages

C1218 Automatic commutation: current too low

Cause
Actual current value amplitude is not sufficient for
exact determination of commutation offset
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
The actual current value amplitude resulting from commutation setting
with the saturation method is monitored. If it does not exceed a minimum
threshold when the command P-0-0524, C1200 Commutation offset
setting command is executed, the command error C1218 is generated.
Remedy
Increase signal voltage (P-0-0506, Amplitude for angle
acquisition) or reduce signal frequency (P-0-0507, Test
frequency for angle acquisition) and restart
commutation setting process
- or -
Enter value "0" in P-0-0506, Amplitude for angle
acquisition. Appropriate value for P-0-0506 is thereby
automatically determined during commutation setting
process
- or -
Reduce value of P-0-0517, Commutation: required
harmonics component, if approx. 30 similar values are
determined for P-0-0521, Effective commutation
offset with repeated commutation setting for different
motor positions (drive remains in "Ab"). Reduce
P-0-0517, Commutation: required harmonics
component until command error C1218 no longer
occurs; finally check function several times!
Note:
If error occurs repeatedly, please contact our service
department.
See also Functional Description "Commutation Setting"
C1218 - Attributes
Display:
C1218
Mess. no.:
C1218 (hex)
Rexroth IndraDrive
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
DOK-INDRV*-GEN-**VRS**-WA01-EN-P

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rexroth IndraDrive and is the answer not in the manual?

Questions and answers

Kaushal patel
January 25, 2025

Our machine in Rexroth drive installation total 20 nos machine so facing issue shortly 5 drive folty 8060 erro so how to do

Table of Contents

Save PDF