Esc+Ru Idm Return(Felica) - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

16.15 RFID
16.15

ESC+RU IDm Return(FeliCa)

IDm return
(FeliCa)
Command
ESC
HEX code
<1B>16
Default Value
aa=00
When turning off the power switch
Valid range within item
Valid range and
term of
command
Valid range between items
[Function]
Returns the result of RFID tag write using <RK> command together with a 64-digit hexadecimal numeric sequence as
a result of IDm+PMm+ID block.
[Format]
Return specification :<RU>,aa
Request to return:[DC2]PK
●Parameters
Symbol
Parameter name
a
Identifier
[[DC2]PK return data format (normal)]
[STX]a...a,b,c,d...d[CR][LF][ETX]
[Return data]
Symbol
Parameter name
Total number of data byte
* This is the total number of bytes after parameter b. The
a
delimiting comma between parameters a and b, and the
ETX are not included.
Write result status
b
Error symbol
c
IDm return data
d
RU
Parameter
<52>16<55>16
,aa
The set command is not maintained.
The set parameter is in effect until a new specification is
made.
The set parameter is in effect until a new specification is
made.
Valid range
00: Not returned (default setting)
01: Validate return
Obtain return data by sending [DC2]PK.
397
ESC+RU
Two character fixation
Valid range
Data size from the first write result
status until before [ETX]
Maximum 5 digits
0: Write failure
1: Write success
Note: Specified in text format.
N:No error
I:IDm read error
A:All errors
Note: Specified in text format
Refer to "IDm return data" as
below
Note: Specified in text format

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents