Esc+Bm Upc-A Barcode (With Hri) - SATO LC400e Series Programming Reference Manual

Hide thumbs Also See for LC400e Series:
Table of Contents

Advertisement

9.16 Barcode
CL408e/412e
Printer
M-8485Se/90Se/60Se/59Se

9.16 ESC+BM UPC-A Barcode (With HRI)

UPC-A Barcode (With HRI)
ESC
HEX Code
<1B>
16
Default Value
NIL
Valid Range &
When Power is Switched Off
Terms of
Valid Range within Items
Command
Valid Range between Items
[Function]
Set the character barcode height of the first and the last digit to the same height of the guard bar.
[Format 1]
<BM>abbcccn~n
●Parameter
a [barcode type]
b [Narrow bar]
c [Height of Barcode]
n [Print data]
[Coding Example]
Barcode type:UPC-A, Narrow bar width:02, Barcode height :120, Print data:
<A>
<H>100<V>100<BM>H0212020123948573
<Q>2
<Z>
[Supplementary Explanation]
1. This command supports UPC-A only. When barcode type is specified other than "H", command error occurs.
2. HRI needs following conditions;
8dot /mm(203dpi) : Set Narrow bar width to [02] or [03]
12dot/mm(305dpi) : Set Narrow bar width to [03] or [04]
When the value other tham above are specified, HRI is not printed.
3. Setting of Guard bar, HRI and Ratio is following.
Guard bar
Available
4. When the parameter value exceeds the range, operation is not supported.
5. All character barcode have the same height when printing UPC-A specifying <D> and then <font>. The first and the last
character barcode have the same height to the guard bar when printing UPC-A specifying <BL> and then <font>.
When printing UPC-A specifying <D> and <font>, HRI can be printed under the first digit and the last digit because the height of the
first digit and the last digit of the barcode is low. When printing UPC-A specifying <BL> and <font>, the height of the first digit
and the last digit of the barcode is high, and the font interval is narrower than previous case.
Guard bar
Character barcode
First digit
UPC-A specifying <BD>
M-8400RVe
CL608e/612e
M-84Pro-2/3/6
BM
<42>
<4D>
16
16
The set parameter is not maintained
The set parameter becomes invalid
The set parameter becomes invalid
= H
: UPC-A( fixed 'H')
= Valid Range
: 01 to 12 dots
= Valid Range
: 001 to 999 dots
= Data
: fixed 11 dight
HRI
Ratio
Available
Fix
Guard bar
Character barcode
Last digit
M-5900RVe
M-10e
LC408e/412e
ESC+BM
Parameter
aaabbcccn~n
Guard bar
Character barcode
First digit
UPC-A specifying <BM>
119
20123948573
Guard bar
Character barcode
Last digit

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents