Commissioning
4.7.5

Diagnostic fault

In the [Extras] [Diagnostics] submenu, you will find various commands for the display of different dia­
gnostic windows. You can find additional information in the SafetyTool Help.
The "Digital I/O (logical states)" window shows, for example, the logical state of the inputs and outputs:
Fig. 4.8
Digital I/O - logical states
The "Error display" window displays the active errors. You can acknowledge them with the "Acknow­
ledge error!" button, if possible here.
Fig. 4.9
Error display
Open the "Functional circuit diagram" window using the menu command [Tools] [Diagnostics] [Internal
signals]. The window shows an overview of the logical and virtual inputs, as well as the virtual and lo­
gical outputs of the safety module.
Clicking one of the blue text links opens an additional window, in which the status of the appropriate
signal group is displayed (in the example, this is the logical inputs represented by the physical inputs).