Product description of safety module CAMC-G-S3
Parameters for SS2
SS2: Safe Stop 2
No.
Name
P0D.00
Time delay until monitoring starts
P0D.01
Time for slowdown ramp
P0D.02
Allowable time for limit value overrun
P0D.06
Actively limit speed in basic unit
P0D.07
Activate quick stop ramp in the basic
unit
P0D.08
Automatic restart permitted
Expert parameter
P0D.0A
Speed ramp - Monitoring time delay
P0D.05
Slowdown ramp - time delay to start
P0D.03
Slowdown ramp - Starting value factor
P0D.04
Slowdown ramp - Starting value offset
P0D.09
Speed offset for the limitation in the
basic unit
Tab. 2.47 SS2: Safe Stop 2
90
Description
Time from the safety function request during
which no rotational speed monitoring takes
place.
The monitoring limits of the SOS function are
used for SS2.
Time from the safety function request, after
which the rotational speed ramps are stopped
and the safe status is reached.
Time interval, during which the actual rotational
speed value may be outside the limits, before the
"Safety condition violated" status is reached.
If set: Control the rotational speed of the basic
unit
If set: When the safety function is requested, the
quick stop command (pilot line) is applied to the
basic unit
If set: Cancellation of the request (restart) if an
inactive request arrives
Time delay between the start of the rotational
speed ramp, written to the basic unit, and the
start of monitoring by the safety module.
Time delay after which the ramps start.
Factor for calculating the starting value of the
rotational speed ramps
Offset for calculating the starting value of the
rotational speed ramps
Offset for rotational speed limits to control the
basic device.