Festo CAMC-G-S3 Manual page 221

Safety module
Table of Contents

Advertisement

5
Operation
Error group 57
Input/output error
No.
Code
Message
57-1
80E2h
Digital inputs - Signal level error
Cause
Action
57-2
-
Digital inputs - Test pulse error
Cause
Action
57-6
-
Electronics temperature too high
Cause
Action
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Exceeding / violation of discrepancy time with multi-channel inputs
(DIN40 ... DIN44, two-handed control device, mode selector
switch).
• Check the external active and passive sensors – do they switch
on two channels and simultaneously (within the parameterised
discrepancy time).
• Two-handed control device: Check how the device is operated
by the user – are both pushbuttons pressed within the discrep­
ancy time? Give training if necessary.
• Check the set discrepancy times – are they sufficient?
– One or more inputs (DIN40 ... DIN49) were configured for the
analysis of the test pulses of the outputs (DOUT40 ... DOUT42).
The test pulses from DOUTx do not arrive at DIN4x.
• Check the wiring (shorts after 0 V, 24 V, cross circuits).
• Check the assignment – correct output selected / configured
for test pulse?
– The safety module's temperature monitor has been triggered;
the temperature of μC1 or μC2 was below -20° or above +75°C.
• Check the operating conditions (ambient temperature, control
cabinet temperature, installation situation in the control cabinet).
• If the motor controller is experiencing high thermal load (high
control cabinet temperature, high power consumption / output
to motor, large number of occupied slots), a motor controller of
the next highest output level should be used.
Reaction
configurable
configurable
configurable
221

Advertisement

Table of Contents
loading

Table of Contents