5
Operation
Error group 59
Internal safety module error
No.
Code
Message
59-4
80F4h
Error management: Too many errors
Cause
Action
59-5
80F5h
Error writing to diagnostic memory
Cause
Action
59-6
80F6h
Error on saving parameter set
Cause
Action
59-7
80F7h
Flash checksum error
Cause
Action
224
– Too many errors have occurred simultaneously.
• Clarify: What is the status of the installed safety module - does
it contain a valid parameter set?
• Read out and analyse the log file of the basic unit via FCT.
• Eliminate causes of error step by step.
• Install safety module with "delivery status" and perform com­
missioning of basic unit.
• If this is not available: Set factory settings in the safety module,
then copy data from the basic unit and perform complete valid­
ation. Check whether the error occurs again.
Consecutive error if internal communication is disrupted.
– Basic unit not ready for operation, faulty or memory error.
• Check the basic unit for function
• Generate an error in the basic unit, e.g. by unplugging the posi­
tion encoder, and check whether the basic unit writes an entry
to the log file.
• Module or basic unit faulty; replace.
– Voltage interruption / power off while parameters were being
saved.
• Maintain a voltage supply of 24 V throughout the parameterisa­
tion session.
• Once the error has occurred, parameterise the module again
and validate the parameter set again.
– Voltage interruption / power off while parameters were being
saved.
– Flash memory in safety module corrupted (e.g. by extreme
malfunctions).
Check whether the error recurs after a reset. If it does:
• Parameterise the module again and validate the parameter set
again. If error persists:
• Module faulty, replace.
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Reaction
Fixed [8]
Fixed [8]
Fixed [8]
Fixed [8]