B
Reference list for control signals and parameters
CO no.
Name
078C
ioh_fsm_proj
_gesamt_rev_idx
0790
ioh_fsm_diag
_ch0
0791
ioh_fsm_diag
_ch1
0792
ioh_fsm_diag
_ch2
0793
ioh_fsm_diag
_ch3
0794
ioh_fsm_dat
_ch0
0795
ioh_fsm_dat_ch1
0796
ioh_fsm_dat_ch2
0797
ioh_fsm_dat_ch3
0798
ioh_fsm_log
_entry_0
0799
ioh_fsm_log
_entry_1
079 A
ioh_fsm_log
_entry_2
079B
ioh_fsm_limit
_speed_upper
079C
ioh_fsm_limit
_speed_lower
079D
ioh_fsm_limit
_torque_upper
079E
ioh_fsm_limit
_torque_lower
079F
ioh_fsm
_deccelramp
Tab. B.13 List of important communication objects in the basic unit
304
Type
Unit
Description
RW
UINT16
--
RW
UINT32
Safety module diagnostics channel 1: Selection of
the COs in the safety module
RW
UINT32
Safety module diagnostics channel 2: Selection of
the COs in the safety module
RW
UINT32
Safety module diagnostics channel 3: Selection of
the COs in the safety module
RW
UINT32
Safety module diagnostics channel 4: Selection of
the COs in the safety module
RO
UINT32
Safety module diagnostics channel 1: Date, dynam­
ically updated by the safety module
RO
UINT32
Safety module diagnostics channel 2: Date, dynam­
ically updated by the safety module
RO
UINT32
Safety module diagnostics channel 3: Date, dynam­
ically updated by the safety module
RO
UINT32
Safety module diagnostics channel 4: Date, dynam­
ically updated by the safety module
RW
UINT32
Enter a log entry in the diagnostic memory of the
safety module. Writing only takes place after the
third entry
RW
UINT32
Enter a log entry in the diagnostic memory of the
safety module. Writing only takes place after the
third entry
RW
UINT32
Enter a log entry in the diagnostic memory of the
safety module. Writing only takes place after the
third entry
RW
INT32
Limiting of rotational speed setpoint, upper limit > 0
RW
INT32
Limiting of rotational speed setpoint, lower limit only
< 0 permitted
RW
INT32
Limiting of torque setpoint, upper limit only > 0
permitted
RW
INT32
Limiting of torque setpoint, lower limit only < 0
permitted
RW
INT32
STOP ramp of the safety module
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English