Festo CAMC-G-S3 Manual page 287

Safety module
Table of Contents

Advertisement

B
Reference list for control signals and parameters
Mapping of the physical inputs to the logical inputs
The physical inputs are mapped to the logical inputs as follows (the stationary status after filtering, test
pulse analysis, etc. is stated):
LIN
Name
96
LIN_D40
97
LIN_D41
98
LIN_D42
99
LIN_D43
100
LIN_D44
101
LIN_D45
102
LIN_D46
103
LIN_D47
104
LIN_D48
105
LIN_D49
1) Valid for configuration as equivalent input. Configuration as antivalent input accordingly: LIN_DIN4x set, when D4xA = 0 V and
D4xB = 24 V.
Tab. B.2
Logical inputs, level assignment to the physical inputs
Please note that LIN_D40 ... LIN_D43 have a special assignment to the voltage levels.
This means that the logical inputs can be fed to the safety functions (e.g. request STO)
without inversion, implementing the idle current principle (input 0 V = STO requested).
Logical inputs after preliminary processing and auxiliary functions
Mapping of the physical inputs after preliminary processing (time expectation, 1-of-n etc.)
LIN
Name
96
LIN_D40
97
LIN_D41
98
LIN_D42
99
LIN_D43
100
LIN_D44
101
LIN_D45
102
LIN_D46
103
LIN_D47
104
LIN_D48
105
LIN_D49
106
LIN_2HAND_CTRL
107
LIN_BRAKE_X6_FB
117
LIN_PWSTG_ON
121
LIN_D45_SAFE
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Function
Bit LIN_D40 set, if DIN40 A/B = 0 V (idle current principle)
Bit LIN_D41 set, if DIN41 A/B = 0 V (idle current principle)
Bit LIN_D42 set, if DIN42 A/B = 0 V (idle current principle)
Bit LIN_D43 set, if DIN43 A/B = 0 V (idle current principle)
Bit LIN_D44 set, if DIN44 = 24 V
Bit LIN_D45 set, if DIN47 = 0 V and DIN46 = 0 V and DIN45 = 24 V
Bit LIN_D46 set, if DIN47 = 0 V and DIN46 = 24 V and DIN45 = 0 V
Bit LIN_D47 set, if DIN47 = 24 V and DIN46 = 0 V and DIN45 = 0 V
Bit LIN_D48 set, if DIN48 = 24 V
Bit LIN_D49 set, if DIN49 = 24 V
Function
Logical status DIN40 A/B
Logical status DIN41 A/B
Logical status DIN42 A/B
Logical status DIN43 A/B
Logical status DIN44
Logical status DIN45; mode selector switch (1 of 3)
Logical status DIN45 - 47 (1 of 3) DIN45
Logical status DIN45 - 47 (1 of 3) DIN46
Logical status DIN45 - 47 (1 of 3) DIN47
Logical status DIN48
Logical status DIN49
Logical status, two-handed control device (pair of 2 x DIN4x)
Feedback, holding brake
Basic unit, output stage active
Logical status DIN45 after mode selector switch analysis
1)
1)
1)
1)
287