5
Operation
Error group 58
Error during communication / parameterisation
No.
Code
Message
58-0
80E9h
Plausibility check of parameters
Cause
Action
58-1
General error, parameterisation
-
Cause
Action
58-4
80E9h
Buffer, internal communication
Cause
Action
58-5
80EAh
Communication module - basic unit
Cause
Action
222
The plausibility check in the safety module produced errors, e.g. an
invalid angle encoder configuration; the error is triggered when a
validation code is requested by the SafetyTool and when paramet
ers are backed up in the safety module.
Note instructions for SafetyTool for complete validation; critic
ally check parameterisation.
Parameter session active for > 8 hrs.
The safety module has thus terminated the parameterisation session
The error message is saved in the diagnostic memory.
Terminate parameterisation session within 8 hrs. If necessary,
start a new parameterisation session and continue.
– Communication connection faulty.
– Timeout / data error / incorrect sequence (packet counter) in
data transmission between the basic unit and safety module.
– Too much data traffic, new requests are being sent to safety
module before old ones have been responded to.
Check communication interfaces, wiring, screening, etc.
Check whether other devices have read access to the motor
controller and safety module during a parameterisation ses
sion - this may overload the communication connection.
Check whether the firmware versions of the safety module and
basic unit and the versions of the FCT PlugIn and SafetyTool are
compatible.
– Packet counter error during transmission μC1 <-è μC2.
– Checksum error during transmission μC1 <-è μC2.
Internal malfunction in the motor controller.
Check whether the firmware versions of the safety module and
basic unit and the versions of the FCT PlugIn and SafetyTool are
compatible.
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Reaction
configurable
configurable
Fixed [8]
Fixed [8]