A.2 Diagnostic Messages With Instructions For Fault Clearance - Festo CiA 402 Manual

For motor controller
Table of Contents

Advertisement

A
Diagnostic messages
A.2
Diagnostic messages with instructions for fault clearance
Error group 01
Internal faults
No.
Code
Message
01-0
6180h
Stack overflow (internal error)
Cause
Action
Error group 02
Intermediate circuit
No.
Code
Message
02-0
3220h
Undervoltage in intermediate circuit
Cause
Action
Error group 03
Temperature monitoring, motor
No.
Code
Message
03-1
4310h
Temperature monitoring, motor
Cause
Action
142
– Incorrect firmware?
– Sporadic high processor load due to special compute-bound
processes (save parameter set, etc.).
• Load approved firmware.
• Contact Technical Support.
– Intermediate circuit voltage falls below the parameterised
threshold.
• Quick discharge due to switched-off mains supply.
• Check mains voltage (mains voltage level or network
impedance too high?).
• Check intermediate circuit voltage (measure).
• Check undervoltage monitor (threshold value).
• Check travel profile: If travel with lower acceleration and/or
travel speeds is possible, reduced power consumption from the
mains results.
Motor overloaded, temperature too high.
– Motor too hot.
– Sensor defective?
• Check parameters (current regulator, current limits).
If the error persists when the sensor is bypassed: Device defective.
Festo – GDCP-CMMS/D-C-CO-EN – 1404NH – English
Reaction
PS off
Reaction
configurable
Reaction
configurable

Hide quick links: