Festo CAMC-G-S3 Manual page 211

Safety module
Table of Contents

Advertisement

5
Operation
Error group 51
Safety module/function
No.
Code
Message
51-1
8092h
Safety function: Driver supply is faulty
Cause
Action
Cause
Action
51-2
8093h
Safety module: Unequal module type
Cause
Action
51-3
Safety module: unequal module version
8094h
Cause
Action
Cause
Action
51-4
Safety module: Error in SSIO communication
8095h
Cause
Action
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Internal hardware error (voltage error) of the safety module or
microswitch module.
• Module presumably defective. If possible, replace with another
module.
– Error in driver circuit section in the basic unit.
• Basic unit presumably defective. If possible, replace with
another basic unit.
Type or revision of the module does not fit the project planning.
• Check whether correct module type and correct version are
being used.
• With module replacement: Module type not yet designed. Ac­
cept currently integrated safety or microswitch module.
Type or revision of the module is not supported.
• Install safety or microswitch module appropriate for the firm­
ware and hardware.
• Load firmware appropriate for the module, see type designa­
tion on the module.
The module type is correct but the module version is not supported
by the basic unit.
• Check module version; if possible use module of same version
after replacement. Install suitable safety or microswitch mod­
ule for the firmware and hardware.
• If only a module with a more recent version is available: Load
firmware that is appropriate for the module, see type designa­
tion on the module.
Fault in the internal communication connection between the basic
unit and the safety module.
• This error may occur if a CAMC-G-S3 was planned for the basic
unit but a different module type was plugged in.
• Load firmware appropriate for the safety or microswitch mod­
ule, see type designation on the module.
Reaction
PSoff
PSoff
PSoff
PSoff
211