Product description of safety module CAMC-G-S3
Parameters for SBC
SBC: Safe Brake Control
No.
Name
P17.00
Time delay, analysis of brake feedback
P17.01
Time delay until "Brake engaged"
signal
P17.02
Analyse holding brake feedback
P17.03
Automatic restart permitted
Expert parameter
P17.04
Cyclical test/deactivate 24 hr.
monitoring
Tab. 2.35 SBC: Safe Brake Control
76
Description
Time from the request of the safety function, by
which the feedback must have come from the
holding brake.
Time delay after request of the safety function
until the "Safe state reached" output becomes
active
If 1: Analyse the feedback of the holding brake.
If 1: Cancellation of the request (restart) if an
inactive request arrives
If 1: The cyclical test of brake activation and
24 hr. monitoring for actuation of the holding
brake by the basic unit is deactivated. The safe
brake output of the basic unit can be used as a
"normal" DOUT with a high acceptable current
load.