B.1.4 Logical Outputs Lout - Festo CAMC-G-S3 Manual

Safety module
Table of Contents

Advertisement

B
Reference list for control signals and parameters
VOUT
Name
48
...
...
62
63
VOUT_SBC_BRK_ON
Tab. B.6
Virtual output signals
B.1.4
Logical outputs LOUT
Like the logical inputs, the status of the logical outputs is represented by 1 bit. This also applies for
two-channel outputs.
Equivalence / antivalence and test signals are processed into physical outputs during the conversion of
the logical outputs.
The logical outputs are combined into a bit vector with a length of 96 bits.
The current status of the bit vector LOUT can be read via the communication objects:
Bit 00 ... Bit 31: P05.12
Bit 32 ... Bit 63: P05.13
Bit 64 ... Bit 95: P05.14
Mapping of the logical outputs
LOUT
Name
0
...
...
63
64
LOUT_D40
65
LOUT_D41
66
LOUT_D42
67
LOUT_RELAIS
68
LOUT_BRK_CTRL
69
LOUT_SS1_RQ
70
...
...
95
Tab. B.7
Logical outputs, mapping of the physical outputs
The physical outputs are assigned to the logical outputs LOUT64 ... LOUT69.
292
Function
Reserved, always zero
Engage holding brake
Function
Logical outputs for diagnostics via fieldbuses
è Section A.4
Status of the output DOUT40
Status of the output DOUT41
Status of the output DOUT42
Status of the signal relay C1/C2
Brake control
SS1 control signal (fixed wiring)
Reserved, always zero
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English