3

Mounting and installation

3
Mounting and installation
3.1
Mounting / removing
The safety module CAMC-G-S3 can only be integrated into the motor controller CMMP-AS-...-M3. It can­
not be operated apart from the motor controller.
Warning
Danger of electric shock if the safety module is not assembled.
Touching live parts causes severe injuries and can lead to death.
Before touching live parts during maintenance, repair and cleaning work and when there
have been long service interruptions:
1. Switch off the power to the electrical equipment via the mains switch and secure it
against being switched on again.
2. After switch-off, wait at least 5 minutes for the equipment to discharge before you
access the controller.
Please note
Incorrect handling can damage the safety module or motor controller.
• Switch off the supply voltage before mounting and installation work. Only switch on
the supply voltage when mounting and installation work is completely finished.
• Never unplug the safety module from, or plug it into, the motor controller when
powered!
• Observe the handling specifications for electrostatically sensitive devices. Do not
touch the components and conductive tracks of the printed circuit board or the pins
of the manifold rail in the motor controller. Only hold the safety module by the front
panel or the edge of the board.