Festo CAMC-G-S3 Manual page 101

Safety module
Table of Contents

Advertisement

2
Product description of safety module CAMC-G-S3
Parameters for SSF
SSF: Safe speed
Parameter no. for ...
SSF0
SSF1
SSF2
P0E.00 P0E.14
P0E.28 P0E.3C Activate SSF
P0E.01 P0E.15
P0E.29 P0E.3D Time delay until monito­
P0E.07 P0E.1B P0E.2F
P0E.08 P0E.1C P0E.30 P0E.44 Safe speed - lower limit
P0E.02 P0E.16
P0E.2A P0E.3E
P0E.03 P0E.17
P0E.2B P0E.3F
P0E.09 P0E.1D P0E.31 P0E.45 Actively limit speed in
P0E.0B P0E.1F
P0E.33 P0E.47 Automatic restart permit­
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Name
SSF3
ring starts
P0E.43 Safe speed - upper limit
Time for slowdown ramp
Allowable time for limit
value overrun
basic unit
ted
Description
If 1: Request of the USF triggers
request of the SSF
Time from the safety function re­
quest during which no rotational
speed monitoring takes place
Final value of the upper ramp at
n
max_end
Final value of the lower ramp at
n
min_end
Time from the safety function re­
quest, after which the ramps are
stopped and the safe state is
reached.
Time interval, during which the
actual speed value may be out­
side the limits, before the "Safety
condition violated" status is
reached.
If set: The speed is transferred to
the basic unit and is limited in the
basic unit.
If 1: Cancellation of the request
(restart) if an inactive request ar­
rives
101