Festo CAMC-G-S3 Manual page 173

Safety module
Table of Contents

Advertisement

4
Commissioning
The operation is indicated by a progress bar. The length of time may vary, depending on the session
variant and the speed of the communication connection.
1
Offline session
2
New paramet­
3
erisation
4
5
6
1
Start the Wizard with the option of also se­
lecting Offline mode
2
Selection of the online session variant
3
Note on the appropriate session variant
Fig. 4.3
Steps to the selection of the online session variant
A parameterisation session can also be started when the drive is switched on. When the parameterisa­
tion session has been started, the drive is switched off by the safety module (no output stage enable).
During a running parameterisation session, all the digital outputs are switched off.
The SafetyTool ends the parameterisation session automatically when you exit the wizard. Then, all the
parameters must have the status "validated". Otherwise, all the changes are lost and the safety mod­
ule starts with the most recently saved and validated parameter set.
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Start online
session
Selection during
online session
New paramet­
Change existing
erisation with
parameterisa­
existing project
tion
Select project
file
Enter a
password
Exit wizard
Transfer safe
parameter set
Select safe
parameter set
4
Selection of a project file / a parameter set
5
Personal identification
6
Exit Start wizard
Display existing
parameterisa­
tion
173