3
Mounting and installation
– Monitoring of the clamping unit checks only actuation and not whether the friction value of the
clamping unit is high enough for it to still be able to function properly.
– The sample circuit has a single-channel structure in the clamping unit, which is suitable up to cat­
egory 2 with a performance test of the clamping unit.
– Additional measures are required according to the scope of application and the safety concept of
the machine.
3.3.6

Activating a 2-channel clamping unit

The safety function (e. g. STO – Safe Torque Off or SS1 – Safe Stop 1) is triggered by an input device for
the safety request. The safety request is sent along 2 channels via the input device S1 and routes to the
2-channel switch-off of the output stage of the motor controller. At the same time, the clamping units
are activated and monitored.
L
N
PE
24 V DC
0 V DC
K1
1
3
Input
device
2
for
safety
request
2
4
1
2
19 20
1
Only relevant connections drawn
1
T1: Motor controller with safety module
(only relevant connections shown)
2
S1: Input device for safety request
Fig. 3.7
Sample circuit, 2-channel clamping unit
156
S2
S3
13
13
S4
14
14
S5
V1
11
12
21 22
13
14
Festo CMMP-AS-...-3A-M3
with CAMC-G-S3
p
Y1
p
2
2
V2
3
1
1
3
19
19
T1
3
V1/V2/Y1: Valves and two-channel clamping
unit
S4/S5: Pressure switch to monitor activation
of the clamping unit
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
9
21
1
2
7
8
9
3

Advertisement

Table of Contents
loading

Table of Contents