Festo CAMC-G-S3 Manual page 100

Safety module
Table of Contents

Advertisement

2
Product description of safety module CAMC-G-S3
The description can be applied in a similar manner to the parameters for the functions SSF1, SSF2 and SSF3.
Thus SSF0 permits adaptation to various application.
In the SafetyTool, the SSF0 parameters are divided up into:
– standard parameters – these are the simple parameters which are to be adapted indi­
vidually to the application for each speed monitoring operation.
– expert parameters – these are parameters for optimisation of the function in conjunc­
tion with the control functions in the basic unit. These parameters are set appropri­
ately at the factory.
In most applications, you will only need the standard parameters!
After the request of the safety function SSF0, the following times elapse until the safety function is
activated and errors are detected:
Time delays from VIN_USF0_RSF
VOUT_USF0_SFR signal
VOUT_USF0_SSR signal
Start of monitoring of the safety
condition according to
VOUT_ZSF0_SFR
Detection of a violation of the
safety condition after P0E.01 or
(P0E.06 + P0E.0D) within
Tab. 2.55 SSF0 time delays
100
min.
max.
2.0 ms
2.1 ms
8.0 ms +
8.1 ms +
(P0E.02 + P0E.0D)
(P0E.02 + P0E.0D)
2.0 ms + MAX
2.1 ms + MAX
(P0E.01 OR
(P0E.01 OR
(P0E.06 + P0E.0D))
(P0E.06 + P0E.0D))
P0E.03
P0E.03
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Typical
2.0 ms
8.0 ms +
(P0E.02 + P0E.0D)
2.0 ms + MAX
(P0E.01 OR
(P0E.06 + P0E.0D))
P0E.03

Advertisement

Table of Contents
loading

Table of Contents