Technical appendix
Resolver
Error acceptance
Short circuit between any two
conductors of the connecting
cable
Interruption of any conductor of
the connecting cable
Static "0" or "1" signal at the in
puts and outputs, individually or
simultaneously at multiple in
puts/outputs
Interruption of high-impedance
status on a single input/output
or multiple inputs/outputs sim
ultaneously
Reduction or increase of the out
put amplitude
Interference vibration on one or
more outputs
Change of phase shift between
output signals
Fastening becomes loose when
idling:
– Sensor housing separates
from motor housing
– Sensor shaft separates from
motor shaft
Mounting comes loose during
movement:
– Sensor housing separates
from motor housing
– Sensor shaft separates from
motor shaft
Measuring element is coming
loose (e.g. optical encoding disc)
No light from transmitter diode
1) DC = 60% applies to factory setting, DC = 90% for restricted tolerances of the vector length monitoring è Appendix A.3
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Fault
Error detection by the
exclusion
safety module
None
Individual signal monitor
ing and vector length mon
1)
itoring
None
Individual signal monitor
ing and vector length mon
1)
itoring
None
Individual signal monitor
ing and vector length mon
1)
itoring
None
Individual signal monitor
ing and vector length mon
1)
itoring
None
Individual signal monitor
ing and vector length mon
1)
itoring
None
Individual signal monitor
ing and vector length mon
1)
itoring
None
Not applicable for resolver
Required!
Not possible safely.
According
However, monitoring of
to manu
the period of the SOS re
facturer's
quest occurs:
datasheet
A switch-off and error
for the
message occur after
encoder
24 hrs.
None
Not applicable for resolver
None
Not applicable for resolver
Supplementary notes/
comments
Error is reliably
detected (DC
of the
AV
safety module)
Error is reliably
detected (DC
of the
AV
safety module)
Error is reliably
detected (DC
of the
AV
safety module)
Error is reliably
detected (DC
of the
AV
safety module)
Error is reliably
detected (DC
of the
AV
safety module)
Error is reliably
detected (DC
of the
AV
safety module)
–
Use fault exclusion for
the motor - encoder
system, or a second
measuring system for
position comparison.
–
–
247