3
Mounting and installation
3.2.2

Functional earth

If you are using a screened connecting cable [X40]:
Keep the unscreened part of the cable as short as possible ( 50 mm), use a short earthing strip with a
6.3 mm flat plug for the screen connection.
Connect the flat plug for the screen connection to the connection for functional earth provided
(è Fig. 2.1 in Section 2.1.4, Connection 7 ).
3.2.3
Connection [X40]
The safety module CAMC-G-S3 has a combined interface for control and acknowledgement via the plug
connector [X40].
– Design on the device: PHOENIX MINICOMBICON MC 1.5/8-GF-3.81 BK
– Plug (included in scope of delivery): PHOENIX MINICOMBICON MC 1.5/8-STF-3.81 BK
The counterplug set, consisting of counterplugs for X40A and X40B can also be ordered
separately: Assortment of plugs NEKM-C-9.
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
145