A.1.3 Operating And Ambient Conditions - Festo CAMC-G-S3 Manual

Safety module
Table of Contents

Advertisement

A
Technical appendix
A.1.3
Operating and ambient conditions
Transport
Temperature range
Air humidity
Maximum transportation
duration
Tab. A.5
Technical data: Transport
Storage
Storage temperature
Air humidity
Permissible altitude
1) Note additional limitations, such as the permissible setup altitude for the motor controller (usually < 2000 m above sea level)
Tab. A.6
Technical data: Storage
Ambient conditions CMMP-AS-...-M3 with safety module CAMC-G-S3 in Ext3
CMMP-AS-...
1)
Ambient temperature
Ambient temperature with
1)
power reduction
Cooling
Air humidity
Permissible setup altitude above sea level
with rated output
with power reduction
Degree of protection
Vibration / shock
1) The maximum permissible operating temperature is dependent on numerous parameters, including the number of switched inputs
and the load of the outputs in the CAMC-G-S3, the equipment of additional modules in EXT1 and EXT2 in the CMMP-AS-M3, the
load of the power output stage in the CMMP-AS-M3 as well as the airflow conditions in the control cabinet.
The specified values apply to a typical device configuration.
The CAMC-G-S3 possesses separate temperature monitoring, which switches the safety module and the basic unit off, if the elec­
tronics temperature becomes too high è Section 5.6 Error 57-6.
Tab. A.7
Technical data: Ambient conditions
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
[°C]
–25 ... +70
[%]
0 ... 95, at max. 40 °C ambient temperature
Maximum 4 weeks over the entire product lifecycle
[°C]
–25 ... +55
[%]
5 ... 95, non-condensing or protected against condensation
 3000 (above sea level)
[m]
C2-3A-M3
C5-3A-M3
[°C]
0 ... +35
0 ... +40
[°C]
+35 ... +40
+40 ... +50
An overtemperature switch-off will take place at a high
power output of the basic unit and/or high load of the con­
trol section and the I/Os.
By means of ambient atmosphere in the motor controller, no
forced ventilation.
[%]
0 ... 90 (non-condensing).
No corrosive media permitted near the device.
[m]
1000
[m]
1000 ... 2000
IP20 (mounted in the CMMP-AS-...-M3).
Requirements of EN 61800-5-1 and EN 61800-2 are fulfilled.
1)
C5-11A-P3-M3 C10-11A-P3-M3
0 ... +40
0 ... +40
+40 ... +50
+40 ... +45
231