Advertisement

4
Commissioning
4.6.7

Configuring digital inputs

The allocation of all single-channel and two-channel inputs is displayed on the "Digital inputs" page.
Editing then takes place separately for each input on the following pages.
Inconsistencies are indicated by an error symbol. In the example, DIN45, DIN46 and DIN47 are para­
meterised as the sensor type "Mode selector switch", but the "Activation" parameter of the mode se­
lector switch is not active.
Now, edit the pages of the digital inputs one after another.
DIN40
• For the example, DOUT42A/B is set as the source of the test pulse.
DIN41
• For the example, "Light curtain" is set as the sensor type and DOUT42A/B as the source of the test
pulse.
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
185