A
Technical appendix
Error acceptance
Interference vibration on one or
more outputs
Change of phase shift between
output signals
Fastening becomes loose when
idling:
– Sensor housing separates
from motor housing
– Sensor shaft separates from
motor shaft
Mounting comes loose during
movement:
– Sensor housing separates
from motor housing
– Sensor shaft separates from
motor shaft
Measuring element is coming
loose (e.g. optical encoding disc)
No light from transmitter diode
Additional requirements for rotary encoders with sin/cos output signals, analogue signal
generation
Static signal at the inputs and
outputs, individually or on mul
tiple signals, amplitude in the
range of the power supply
1) Sensitivity and DC in accordance with the parameterised fault limits; specification applies to factory setting
2) Position information is "static" if there is a fault => Fixed commutating position, motor at idle / voltage of a channel static
=> Commutating position changes by max +/-90° of a signal period of an encoder, motor only moves in this range
244
Fault
Error detection by the
exclusion
safety module
None
Individual signal monitor
ing and vector length mon
1)
itoring
None
Individual signal monitor
ing and vector length mon
1)
itoring
Required!
Not possible safely.
According
However, monitoring of
to manu
the period of the SOS re
facturer's
quest occurs:
datasheet
A switch-off and error
for the en
message occur after
coder
24 hrs.
None
Individual signal monitor
ing and vector length mon
1)
itoring
None
Individual signal monitor
ing and vector length mon
1)
itoring
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Supplementary notes/
comments
In accordance with sec
tion A.3;
2)
DC > 90%
When a signal oscil
lates, maximum motor
movement in the toler
ance window of the
amplitude monitoring
In accordance with sec
tion A.3;
2)
DC > 90%
e.g. through a soiled
code disc
Use fault exclusion for
the motor - encoder
system, or a second
measuring system for
position comparison.
In accordance with sec
tion A.3;
2)
DC > 90%
In accordance with sec
tion A.3;
2)
DC > 90%