Disassembly And Installation - Festo CAMC-G-S3 Manual

Safety module
Table of Contents

Advertisement

6
Service, repair, replacement, waste management
6.3.1

Disassembly and installation

Before a module is replaced, compatibility between the safety module and basic unit must be checked,
see also è Section "Versions" at the front of this document.
Information on disassembling and installing the safety module can be found under Mount­
ing/dismounting the safety module è Section 3.1.
Tip: If the safety module to be replaced can be contacted from the SafetyTool, we recommend saving a
safe parameter set of the validated actual status (start the SafetyTool in Online mode - display the
parameterisation - then generate a safe parameter set).
6.3.2
Accepting safety module
After replacing the module, you must first accept the new safety module again in the FCT PlugIn CMMP-AS.
Accept the serial number of the replaced safety module è Section 4.3.4.
6.3.3
Recommissioning with the SafetyTool
After accepting the replaced safety module, you must transfer the desired parameterisation to the
safety module and then validate it.
Basic information can be found in the following sections:
– SafetyTool è Section 4.5
– Parameterisation è Section 4.4
– Performance test and validation è Section 4.8
To do this, you must first start the SafetyTool in the online mode.
You then have the following options, depending on which data is present from the safety module to be
replaced:
a) A reliable parameter set of the safety module to be replaced is available:
• Open the parameter set in the SafetyTool and load it to the safety module. For this, the basic
information of the basic unit must agree with that contained in the parameter set.
b) A stored SafetyTool project that agrees with the current parameterisation is available:
• Set the safety module to the factory setting, if it is not in the delivery status.
• Then open the SafetyTool project.
• The basic information of the basic unit must agree. Otherwise, you must synchronise it.
• Then, you can validate the individual parameter pages and load them to the safety module.
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English