Table of Contents

Advertisement

A
Technical appendix
Safety data
Values in accordance with EN ISO 13849-1
1)
Category
1)
Performance Level
-1
PFH
[h
]
DC
[%]
MTTF
[Years] 8700
d
T
[Years] 20
M
1) Maximum achievable classification, limitations dependent on the safety function è Section 1.1.4, Tab. A.16 as well as the circuitry
and the encoders è Appendix A.2
Tab. A.1
Technical data: Safety data
Safety information
Type test
Certificate-issuing authority
Certificate no.
Reliable component
Tab. A.2
Technical data: Safety information
A.1.2
General
Mechanical
Length / width / height
Weight
Slot
Note on materials
Tab. A.3
Technical data: Mechanical
Certifications (safety module CAMC-G-S3 for motor controller CMMP-AS-...-M3)
CE marking (see declaration of
conformity) è www.festo.com
Tab. A.4
Technical data: Certifications
230
4
Category
PL e
Performance Level
–9
9.5 x 10
Average probability of a dangerous failure per hour
97.5
Diagnostic coverage
Mean time to dangerous failure
Mission time
The functional safety design of the product was certified by
an independent testing authority in accordance with section
1.1.4; see EC-type examination certificate
è www.festo.com/sp
TÜV Rheinland, Certification Body of Machinery, NB 0035
01/205/5165.01/14
Yes
[mm]
112.2 x 99.1 x 28.7
[g]
220
Slot Ext3 for safety module
RoHS-compliant
According to EC Machinery Directive 2006/42/EC
To EU EMC Directive
The device is intended for use in an industrial environment.
Additional measures for interference suppression may need
to be implemented in residential areas.
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English