Page 4
Contents and general instructions ® ® PROFINET IO , PROFIBUS are registered trademarks of the respective trademark owners in certain countries. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
... means that failure to observe this instruction may result in material damage. In addition, the following pictogram marks passages in the text which describe activities with electrostatically sensitive devices: Electrostatically sensitive devices: Incorrect handling may cause damage to components. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 9
Recommendations, tips and references to other information sources. Accessories: Specifications on necessary or useful accessories for the Festo product. Environment: Information on the environmentally friendly use of Festo products. Text designations Bullets denote activities that may be carried out in any • desired order.
To ensure the safety level: Switch on each output channel used at least once every • 8 hours of operating time for longer than 1 minute. The operating time starts with the first switch-on of the output module. VIII Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
(auxiliary sup- ply DC 24 V). The output channels of the CPX-FVDA-P2 form with their con- nected consumers one safety circuit each. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Rules for product configuration – Operation of the output module CPX-FVDA-P2 is permiss- ible only in CPX terminals from Festo of the variant CPX-M-..– All technical operating limits must be complied with Technical data).
Page 13
If the residual current is exceeded, operative malfunctions are possible. Tab. 0/2: Permissible valve types – The operation of switch-off groups within CPX valve ter- minals is allowed only in combination with permissible pneumatics ( description for the respective valve ter- minal). Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 14
For configuration of the CPX-FVDA-P2 only the following components are permissible: Component Type Interlinking block CPX-M-GE-EV-FVO Connection block CPX-M-AB-4-M12X2-5POL CPX-AB-8-KL-4POL Tab. 0/4: Permissible components Further information about the supported product designs of CPX can be found in section 1.1.2. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
VTSA, MPA-S, MPA-F, MPA-L ( Tab. 0/2) – in a CPX terminal with connected valve terminal that is equipped with VPPM – in impermissible switching configurations chapter 1.3.2 application examples) XIII Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 16
A professional replacement of the electronics module by the user is permissible. Note In the event of damage caused by unauthorised manipula- tion or other than intended use, the guarantee is invalid- ated and the manufacturer is not liable for damages. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
– Observe operating voltage limits – Comply with temperature range – Use max. 2 output channels in a shared safety-oriented control circuit Additional measures for avoidance of common cause faults may result from the application. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Mount cable entries and seals professionally – Seal unused connections with cover caps After a safety demand, such as emergency stop, make • sure that the system restart takes place only under con- trol of the safety controller. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 19
– the applicable regulations for accident protection and industrial safety – the documentation for the product Note Work on safety-related systems should only be carried out by authorised specialists trained in safety engineering. XVII Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
• The original packaging offers sufficient protection from typical stresses. Service Please consult your local Festo repair service if you have any technical problems. Range of application and certifications The product is a safety component as defined in the Ma- chinery Directive 2006/42/EC and carries the CE marking.
Page 21
– The technical data in this documentation may show val- ues deviating from this. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
– Production time period (encoded) 7 (here A5 = May 2010) Part number of the electronics module CPX-FVDA-P2 Permits tracking of the product. Tab. 0/7 and Tab. 0/8 Tab. 0/6: Name plate of the electronics module CPX-FVDA-P2 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 23
B = 2011 C = 2012 D = 2013 E = 2014 F = 2015 H = 2016 J = 2017 K = 2018 L = 2019 M = 2020 Tab. 0/7: Manufacturing year (20-year cycle) Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 24
Contents and general instructions Manufacturing month January February March April June July August September October November December Tab. 0/8: Manufacturing month XXII Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
English on the operator unit are shown in square brackets in this description, e.g. [Debounce time]. Next to this in the text follows the translation, e.g.: Input debounce time [Debounce time]. XXIII Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Safety controller for control of safety-related devices Forced dynamisation Procedure for function checking of a device’s switching capability. The effectiveness of the P- and M-switches of the output module CPX-FVDA-P2 are checked cyclically for their operational capability. XXIV Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 27
– PL a is the lowest and PL e the highest level. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 28
PROFIsafe-capable device or module through DIL switches. Configuration errors can be determined automatically through comparison between the set and actual configuration. PROFIsafe monitoring Monitoring time for the safety-oriented communication between F-HOST time and F-Device XXVI Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 29
Safety-oriented Exchange of safety-related messages between F-Host and F-Device (e.g. via communication PROFIsafe) Safety-oriented Safety circuit including safety-oriented activation through the controller. control circuit XXVII Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 30
Wire break detection Function that detects and reports connection errors, such as loads without contact and wire break. For CPX-FVDA-P2, this function can be activated or deactivated through parameterisation. Tab. 0/9: Product-specific terms and abbreviations XXVIII Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
In addition, the output module offers two output channels (CH1 and CH2) that, on request, can also be switched off in a safety-oriented manner (P- and M-switching). These output channels are supplied from the load voltage supply for valves Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 34
0 V ; available through the connection technology of the module CPX-FVDA-P2 Processors for control and monitoring of the P- and M-switches Fig. 1/1: Circuit diagram of the CPX power supply concept with CPX-FVDA-P2 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 35
U from an output chan- nel (CH1 or CH2). If requested (in the functioning case), the load of the additional valve terminal is switched off without influencing the communication and input func- tion. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 36
1. System overview CPX-FVDA-P2 Note Use max. 2 output channels in a shared safety-oriented • control circuit. Information on the voltage supply concept of the CPX termin- al can be found in the CPX system description. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
To avoid errors in mounting, both the interlinking block CPX-M-GE-EV-FVO and the electronics module CPX-FVDA-P2 are mechanically coded. The coding prevents a different module from being plugged into the interlinking block or the electronics module from being plugged into an incorrect interlinking block. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 38
– Connections are arranged in groups of 4, one functional-earth connection per group Tab. 1/1: Permissible connection block Connection blocks are not mechanically coded. Use of a different connection block than the ones named here is impermissible. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 39
CPX terminal are switched off in two channels, P and M-sided. The connected external consumers are switched off in two channels, P- and M-sided. The output channels 1 und 2 (CH1, CH2) are supplied from U Tab. 1/2: Electronics module Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 40
To the right of the output module, a U is no longer available above the contact rails. Tab. 1/3: Interlinking block Use of a different interlinking block for CPX-FVDA-P2 is imper- missible. 1-10 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 41
Valve terminal MPA-S with CPX modular electrical peripherals – MPA-S-FB-VI Valve terminal type 33 Valve terminal MPA-F with CPX modular electrical peripherals – MPA-FB-VI Valve terminal type 34 Valve terminal MPA-L with CPX modular electrical peripherals – MPA-L-FB-VI 1-11 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 42
Set the parameter “Wire break monitoring” of the pneu- • matics interface to inactive ( parameter description for the pneumatics interface). Otherwise, diagnostic errors can be triggered in certain cases by the module’s self-monitoring. 1-12 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 43
VTSA-... or VMPAL-... are used, the diagnostic message “wire break” can be triggered, since the detection limit has been fallen below. In this case, deactivate the “wire break” diagnostic • message for the output channel CH0. 1-13 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
2 bytes for F user data of the module PROFIsafe data 1 byte status or control byte Embedded PROFIsafe telegram 3 bytes CRC signature (CRC2) Fig. 1/4: Telegram structure of the output module CPX-FVDA-P2 1-15 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
The 6 bytes for inputs are made up of the following: – 2 bytes of input data (F-user data, Tab. 1/8) – 1 byte control byte (for PROFIsafe communication) – 3 bytes CRC (for PROFIsafe communication) 1-16 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
This reduces the error potential for the connected load. The other diagnostic measures remain active. With active monitoring, a cyclical check of the switch-off paths takes place. The function of the electronic switches and 1-17 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 48
If the function is active (1 = on), in case of a channel error, the output module safely switches off only the output channel in which the error occurred. Uninvolved output channels re- main uninfluenced and the module remains integrated. 1-18 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 49
0-signals. In case of passivation of an output channel, the corresponding bit supplies a logic 0. Tab. 1/8: Bit pattern of the input data (F-user data, byte 0 and byte 1) 1-19 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 50
Bit in the output image ( Tab. 1/7) Bit in the input image ( Tab. 1/8) X = Signal irrelevant; 1 = logic 1; 0 = logic 0 Tab. 1/9: Sequence description of channel fault acknowledgment – example 1-20 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 51
Make sure that (in the F-Host) bit 4 of byte 1 of the input • image of the F-user data is regularly checked for “1”. Also make sure that, if a “0” is read in, the relevant mod- • ule in the controller is immediately passivated. 1-21 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
In this case, the output channel is switched off for safety. Make sure that a load is operated with sufficiently low • own dynamics at the output channel involved. 1-22 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
(e.g. valves, contactors, relays) cuits ... of the load voltage of external elec- tronic consumers with safe galvanic isol- ation of the load voltage Tab. 1/10: Possible applications for the output module CPX-FVDA-P2 1-23 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 54
Output module CPX-FVDA-P2 with Galvanic isolation interlinking block CPX-M-GE-EV-FVO Electronics side Valve terminal MPA or VTSA Solenoid coils of the internal pneumatics Fig. 1/5: Switch-off of the load voltage supply of CPX-internal solenoid coils 1-24 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 55
An internal or external valve group can, for example, be ex- hausted through an external exhaust valve. M CH1/2 24 V P CH1/2 0 V CH1/2 +24 V CH1/2 Output module CPX-FVDA-P2 Potential-free passive load Fig. 1/6: Safe switch-off of potential-free individual consumers 1-25 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 56
Load side of the consumer, galvanic- ally isolated Fig. 1/7: Safe switch-off of the load voltage of external electronic consumers with safe galvanic isolation of the load voltage 1-26 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
On the following pages, you will find various application examples representing the switching of permissible and impermissible safety circuits. Caution Make sure that the application examples designated • impermissible are not used under any condition. They merely represent a foreseeable misuse. 1-27 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 58
Output module CPX-FVDA-P2 with Solenoid coils of the internal interlinking block CPX-M-GE-EV-FVO pneumatics CPX valve terminal MPA or VTSA Galvanic isolation Electronics side Fig. 1/8: Connection of the load voltage supply of CPX-internal solenoid coils 1-28 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 59
0 V CH1/2 +24 V CH1/2 M CH1/2 24 V P CH1/2 0 V CH1/2 +24 V CH1/2 Output module CPX-FVDA-P2 Potential-free parallel passive loads Potential-free passive load Fig. 1/9: Safe connection of potential-free individual consumers 1-29 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 60
+24 V CH1/2 Output channel CH1 or CH2 of the Safety relay 2 with forced feedback output module CPX-FVDA-P2 contact Safety relay 1 with forced feedback contact Fig. 1/10: Safe connection of safety relays 1-30 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 61
Output channel CH1 or CH2 of the Output channel CH2 or CH1 of the output module CPX-FVDA-P2 output module CPX-FVDA-P2 Safety relay 1 Safety relay 2 Fig. 1/11: Impermissible connection of potential-free individual consumers, using safety relays as an example 1-31 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 62
Shared guiding of the signals over the same cable permissible Safety-relevant load circuit Galvanic isolation Fig. 1/12: Connection of general active loads If supply is from the output module, a functional galvanic isolation is sufficient. 1-32 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 63
Galvanic isolation NECA-S1G9-P9-MP5 with Supply of the MS6-SV-..-E-10V24-… via MS6-SV-..-E-10V24-… NECA-S1G9-P9-MP5 Antivalent control ports EN1, EN2 Shared guiding of the signals over the same cable permissible Fig. 1/13: Connection of an MS6-SV-..-E-10V24-… via NECA-S1G9-P9-MP5 1-33 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 64
Fig. 1/14: Connection of an MS6-SV-..-E-10V24-… via NECA-S1G9-P9-MP5 to both output channels CH1 and CH2. With the second output channel, a reset and thus acknow- ledgment of an MS6-internal error switch-off can be triggered by briefly switching off the MS6-supply. 1-34 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 65
P CH2/1 0 V CH2/1 +24 V CH2/1 2 x output module CPX-FVDA-P2 Antivalent control ports EN1, EN2 NECA-S1G9-P9-MP5 with Supply of the MS6-SV-..-E-10V24-… via MS6-SV-..-E-10V24-… NECA-S1G9-P9-MP5 Fig. 1/15: Impermissible connection of an MS6-SV-..-E10V24-… 1-35 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 66
Part of the valve terminal with the output module CPX-FVDA-P2 valves to be switched off for safety engineering reasons Additional power supply VMPA…-FB-SP-…-V-… Fig. 1/16: Connection of a valve terminal via additional power supply 1-36 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 67
Note Use only the approved output modules in the safety • circuit. Observe the specifications for connection of loads to an • output module within the safety circuit ( chapter 1.4.2 and example 12). 1-37 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 68
Use only the approved output modules and valve • terminals in the safety circuit. Observe the specifications for connection of loads to an • output module within the safety circuit ( chapter 1.4.2 and example 12). 1-38 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 69
Fig. 1/19: Connection of additional loads via an output module Note Use only the existing connections for supply of the • additional loads. Connect the additional loads in a potential-free manner • (no reference to FE or PE). 1-39 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 70
Functionally switched loads that are put module CPX-FVDA-P2 disconnectable for safety engineering reasons Internal system bus for functional con- trol of the loads Operating voltage supply, galvanically isolated 0V-potential, which does not come from M, e.g. V 1-40 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
– from the load voltage supply for valves (U Note If electronic loads are connected to CH1 and CH2, under unfavourable operating conditions, the result may be in- correct detection of a cross circuit. 1-41 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 72
For operation of the valve terminal, make sure that the • maximum permissible load current is not exceeded. Therefore, limit the number of simultaneously switched- on valves. Otherwise, the safety-oriented switch-off of the relevant safety circuit will take place. 1-42 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Make sure that the voltage supplies used come from the • same source to ensure functioning of the cross circuit detection. Always connect the load to the related 0V port located on • the output module. 1-43 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 74
Make sure that CH1 and CH2 are not switched electric- • ally parallel. Note Make sure that all voltages in the system (for CPX and its • loads switched for safety engineering reasons) refer to the same functional earth (FE). 1-44 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
The use of PELV circuits ensures protection from electric shock (protection from direct and indirect contact) in accord- ance with IEC/EN 60204-1 (Electrical equipment of machines, general requirements). In addition, compliance with the input voltage limits of the module is ensured. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 78
CPX-M-GE-EV-Z. Note When the intermediate power supply CPX-M-GE-EV-Z is mounted on on the right side of the interlinking block CPX-M-GE-EV-FVO, the safety function of output channel CH0 is ineffective. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Instructions can be found on the following pages and in the appendix A.2. Use plugs from the Festo assortment www.festo.com/catalogue). The max. permissible line length is 200 m.
Page 80
For sealing, use the specified cover from the accessories • www.festo.com/catalogue). Note Cross-circuit monitoring is only for the device’s own cir- cuits. Make sure that cross-circuiting to other circuits is pre- • vented through appropriate installation measures. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Channel error LED per output channel (red) Module error LED (red) FP-LED (green) Module identifier FVDOP2 (for CPX-FVDA-P2) Area for electrical connections Fig. 2/1: Display and connecting elements CPX-FVDA-P2 Detailed information on the LEDs section 5.3. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 82
All output voltages are likewise derived from the internal contact rail U Tab. 2/1: Pin allocation with M12 connection block CPX-M-AB-4-M12X2- The metal thread of the connection block 5POL is connected internally with pin 5 (functional earth FE). Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 83
= free (not connected) Unswitched voltage U usable for supply of intelligent load systems (auxiliary supply) All output voltages are likewise derived from the internal contact rail U Tab. 2/2: Pin allocation with KL connection block Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Electronics modules include electrostatically sensitive devices. Observe the handling specifications for electrostatically • sensitive devices. Discharge yourself from static discharges before assem- • bling or disassembling modules to protect the modules. 2-10 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 85
Fig. 2/2: 10-element DIL switch for setting the PROFIsafe address – binary coded Note Before commissioning of the automatic system, make • sure that the PROFIsafe address is set in accordance with the installation planning. 2-11 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 86
When mounting, observe the instruction in section 2.5.2 (threaded connector without distortion, clean connection surfaces, etc.). 4. Remount the connection block. Tightening torque Technical data (appendix A.1). 2-12 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
The plugs connected to the connection block at the CPX- M-AB-4-M12X2-5POL or cable at the CPX-AB-8-KL-4POL can remain attached while dismounting the connection block. 2-13 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
1. Switch off the operating and supply voltage. 2. Unscrew the screws 9 and carefully lift off the connection block 1. 3. If required: Pull the electronics module 2 carefully off the contact rails. 2-14 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Before mounting, make sure that the PROFIsafe address • is correctly set at the electronics module ( section 2.4). To mount the electronics module and connection block Fig. 1/2 in section 1.1.1): 1. Switch off the operating and supply voltage. 2-15 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 90
1 in the right position and place it onto the elec- tronics module 2. 4. Set the screws so that the self-cutting threads can be used. Tighten the screws by hand in diagonally opposite sequence; tightening torque: 0.9 ... 1.1 Nm. 2-16 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
The basic procedure and the required configuration data are presented in the following pages. 3.1.1 Device master file (GSDML and GSD) In combination with the output module CPX-FVDA-P2, you need a current device master file GSDML/GSD for configura- tion and programming. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 94
3. Commissioning Source Current versions of the GSDML/GSD files for CPX terminals can be found on the Festo website at: – www.festo.com/fieldbus Import the GSDML/GSD file into the project of the configura- tion program. After import, you can select the CPX terminal with the output moduleCPX-FVDA-P2 in the configuration program and edit it (e.g.
3. Dismantle the connection block of the output module section 2.5.1). 4. Check the module for excellent status. 5. Set the PROFIsafe address through the DIL switches on the module and mount the connection block section 2.5.2). Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
If necessary, set standard parameters of the output module ( section 3.5 and 3.5.1) 3. Create and load the safety program. 4. Commission the CPX terminal on the fieldbus (PROFIBUS or PROFINET IO) and test the characteristics in trial mode. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
(not F_iPar_CRC has been extended parameters available. change- by 4 bytes. The parameter able) F_Block_ID has the value 1 if the parameter F_iPar_CRC is on hand; otherwise it has the value 0. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 98
F_iPAR_CRC CRC through the individual – CPX-FVDA-P2 makes no – 0 device parameters individual device (not (i-parameter). parameters available. change- able) Tab. 3/3: PROFIsafe parameters Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Switching off of the diagnostics in case of undervoltage identification U makes sense if another module connected to the switched voltage (e.g. a pneumatics interface) has its own undervoltage detection and can initiate a corresponding error message. Tab. 3/5: Monitoring of supply voltage U 3-10 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 101
Deactivating the wire break monitoring is necessary if: – a load smaller than the minimum-specified load is to be switched or – the electrical signal is guided additionally through external relays that them- selves disconnect the circuit. 3-11 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 102
SW 0 Bit 1: SW 1 Bit 7: SW 7 High byte 4828 + m * 64 + 23) Bit 0: SW 8 Bit 1: SW 9 Bit 2 ... 7: reserved or 0 3-12 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 103
SW 9 SW 8 high byte 0: switch element is OFF 1: switch element is ON Note This parameter can only be changed by changing the DIL switch setting (read only). Tab. 3/8: DIL switch setting 3-13 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Module identifier in the main menu Module identifier in the header of the (here as third module) system sub-menu for a module Fig. 3/1: Module identifier of the output module CPX-FVDA-P2 at the operator unit 3-14 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 105
Parameters (P) – basic representation Diagnostics (D) Module data (MD) Fig. 3/2: Special representations for CPX-FVDA-P2 on the operator unit When the command [Monitoring/Forcing (M)] is called up, the statuses of the 3 output channels are displayed. 3-15 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
In the configuration table, click on the line of the output • module CPX-FVDA-P2. Then the dialogue window “Properties – FVDA-P2” appears. Now set the desired start addresses of the inputs and • outputs in the [Addresses] tab of the dialogue window Fig. 3/3). 3-16 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 107
Output module CPX-FVDA-P2 in the configuration table of the CPX terminal Start addresses of the output module for inputs and outputs (here 44) Fig. 3/3: CPX terminal configuration with Siemens STEP 7 – HW Config 3-17 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 108
Observe that not all PROFIsafe parameters shown here are relevant for the output module. Detailed information on the individual parameters can be found in section 3.5.1. Fig. 3/4: Standard parameters of the output module CPX-FVDA-P2 3-18 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 109
[F_Dest_Add] ( Fig. 3/5). The setting must match the DIL switch setting on the module ( Fig. 2/2). Detailed information on the individual parameters can be found in section 3.4. Fig. 3/5: PROFIsafe parameters 3-19 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 110
F-user data (each 2 bytes inputs and outputs) Output module CPX-FVDA-P2 (each 6 bytes of inputs and outputs) Not usable range (each 1 byte for status/control and 3 bytes CRC) Fig. 3/6: Addressing example 3-20 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 111
VABV-S4-1-T2... – VTSA: pneumatics module – – VABV-S4-2-T2... ) The number of allocated output addresses is specified by DIL switches (here 8DO) Tab. 3/9: Input and output addresses for the example ( Fig. 3/6) 3-21 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 112
3. Commissioning 3-22 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
The LED display of the module is not designed in a safety- oriented way. Observe that the LEDs must not be evaluated for safety- • oriented measures. Detailed information on this error response can be found in section 5.2 and 5.3.2. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Module Event/ status error error illus- tration Output channel is switched on Output channel is switched off Refers to the output channel that is assigned to the respective status LED. Tab. 4/2: Normal operating status Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 117
Diagnostics and error handling Chapter 5 Diagnostics and error handling Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 118
........5-12 5.4.1 Diagnostics with the operator unit CPX-MMI ....5-12 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
LED and, if necessary, can be evaluated with the operator unit. Information on diagnostics options of the complete CPX ter- minal or all modules can be found in the CPX system descrip- tion or in the description for the CPX bus node used. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
F_WD_Time) • Acknowledgment and reentry of the module • [Leakage current] Cross circuit error (bypass circuit Eliminate cross circuit • error) at the output Acknowledgment and reentry of the module or output channel Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 121
When PROFIBUS is used, all error messages without standardised error type are mapped to error type 9. When PROFINET is used, the error message 69 is transmitted as diagnostic message 72, and the error message 65 as diagnostic message 64. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
LED 2 do not light up. Note The LED display of the module is not designed in a safety- oriented way. Observe that the LEDs must not be evaluated for safety- • oriented measures. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 123
Wire break Replace affected cable Error- specific LED flashing Cross circuit at the output Eliminate error or short circuit/overload error at the output (de- pendent on error number) illuminated Tab. 5/4: Channel error LED Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 124
The PROFIsafe communication can- slowly parameter not be constructed. – Operator Acknowledge – PROFIsafe: 0A-Req possible LED flashing quickly – Failsafe protocol active – Module communicates with an F-Host via PROFIsafe protocol. illuminated Tab. 5/6: FP-LED Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
65, 66, 67, 69 Undervoltage Self-test error Error no. 61 overvoltage Parameter “Monitoring of Parameter “General diagnostics undervoltage in valves” module” Parameter “General diagnostics Failsafe protocol” Fig. 5/2: Principle of error handling and parameterisation – part 1 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 126
Cross circuit output output channel 0 channel 1 ... 2 or 80 or 80 Module parameters (switch position represented = default setting) Channel-specific error Fig. 5/3: Principle of error handling and parameterisation – part 2 5-10 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 127
If “channel-wise passivation” is active, only the affected output channel is passivated. Otherwise Does not result in safety switch-off. In many cases, channel-error LEDs are also illuminated. Tab. 5/7: Behaviour in the event of an error 5-11 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
(module 3 here) Current module error (here none) Fig. 5/4: Module identifier of the output module CPX-FVDA-P2 on the operator unit In addition, the operator unit offers access to the diagnostic memory ( description P.BE-CPX-MMI-1-...). 5-12 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
• modalities of the return. In case of complaint or repair, please name the following specifications: claim type 2 in accordance with Festo VA 19.02. For dismounting and mounting of the electronics module section 2.5. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
6. Service, repair, disposal Disposal The material used in the packaging has been specifically chosen for its recyclability. For the final disposal of the output module, please contact a certified waste management company for electronic waste. Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 133
Technical appendix Appendix A Technical appendix Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 134
Technical data of the interlinking block ......A-10 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 135
Potential reference of the output channels Max. power supply CH0, CH1, CH2 (load current per output channel) Max. load current per unswitched voltage (auxiliary supply) Max. peak current per output channel 5 for t < 30 ms Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 136
Fig. A/1 Fuse protection (short circuit) Integrated electronic fuse Max. test pulse duration [µs] Max. voltage drop during test pulse Tab. A/1: Electric characteristic values Fig. A/1: Maximum permissible load inductivity at the output channels Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 137
) at the output channels CH1 and CH2 WCDT dependent on the minimum load PROFIsafe watchdog time F_WD_TIME Max. response time of the safety function [ms] F_WD_TIME + T WCDT Max. cyclical request rate [1/min] Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 138
To guarantee the safety level, a minimum switch-on duration of 1 minute for every 8 operating hours must be planned for each output channel used. Profile for Safety Technology on PROFIBUS DP and PROFINET IO; Version 2.4, March 2007 Tab. A/3: Safety characteristics Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 139
Fig. A/2: Internal response time dependent on the minimum load current Note Use the following diagram if load resistance is known. • [Ohm] Load Fig. A/3: Internal response time dependent on the Ohmic minimum load Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 140
EN 60 529 Electromagnetic compatibility Declaration of conformity – Emitted interference (www.festo.com) – Resistance to interference UL certification c UL us - Recognized (OL) Chapter A.2 “Technical data of the connection blocks” Tab. A/5: Other characteristic values Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 141
Reinforced polyamide, polycarbonate Ports – Design 2 terminal strips – Contact load capacity Degree of protection is determined through a combination of interlinking block and connection block Tab. A/7: Technical data for connection block CPX-AB-8-KL-4POL Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 142
Die-cast aluminium Function Interrupts all contact rails for load voltage supplies (U switchable, U permanent) Special feature Mechanical coding prevents plugging in of impermissible electronics modules Tab. A/8: Technical data for interlinking block CPX-M-GE-EV-FVO A-10 Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 143
Index Appendix B Index Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...
Page 144
............Festo P.BE-CPX-FVDA-P2-EN en 1209NH English...