4
Commissioning
3. In the right-hand "Operands" frame, select LIN_D40 and apply the entry with "Operands: Ins.". Alternat­
ively, you can drag the entry onto the driver link with the mouse (here: Product term P04.00).
4. Then select LIN_D45_SAFE and apply the entry with "Gate: Ins.". Alternatively, you can drag the
entry onto the OR gate (≥ 1) with the mouse. This inserts a new gate with the entry LIN_D45_SAFE
(in the example: Product term P04.07).
5. Now, under "Gate", select the LIN_D45_SAFE entry you have just created, in order to highlight the
second gate as the target for the insertion of additional operands (here: Product term P04.07).
6. Then, in the right-hand "Operands" frame, select LIN_D41 and apply it with "Operands: Ins.".
Alternatively, you can drag the entry onto the driver link with the mouse. The driver automatically
turns into an AND operation.
7. After transmission, you must now validate 2 product terms using the OR operation.
In the example, the setting in the "Terminate request" tab can be left as LIN_D49_RISING_EDGE.
SS2: Safe Stop 2
1. In the "Standard Parameter" tab, check the settings and adapt them to your application as neces­
sary è Section 2.5.4.
For the example, create the following logic in the "Request" tab: