Festo CAMC-G-S3 Manual page 62

Safety module
Table of Contents

Advertisement

2
Product description of safety module CAMC-G-S3
Digital Input DIN44
High -> Low
DIN44
P02.19
LIN_D44
Low -> High
DIN44
LIN_D44
Fig. 2.12 Timing diagram of single-channel input (example DIN44)
After the request of a control function via DIN44 ... DIN49, the following times elapse until the logical
input LIN_D... is switched to active:
Time delays from the level change
Ts
Filter time constant (P02.18/1A/1C/1E/20/22)
Reaction time
Tab. 2.25 Time delays DIN44 ... DIN49
Tab. A.10 è in Appendix A.1 describes the technical data for the control ports within the
specified operating range of the logic voltages in accordance with EN 61131-1.
62
Ts < 2.5 ms
Ts < 2.5 ms
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
P02.18
P02.19
P02.18
Minimum
Maximum
0.5 ms
2.5 ms
1.0 ms
10.0 ms
1.5 ms
12.5 ms
Typical
1.5 ms
3.0 ms
4.5 ms

Advertisement